G1000 NXi System Maintenance Manual
Page 88
King Air 300 Series
Revision 1
190-00716-N1
On the MFD, database verification messages may appear. If so, follow the on-screen
instructions to continue.
Go to the MFD Aux - Databases page to monitor the automatic database update
progress. The new databases will show “Syncing” to the Standby column. After the
databases are synchronized, the system will verify them for use by showing “Verifying” in
the Standby column. After the databases are verified, a cyan double arrow symbol will
appear between the Standby and Active columns to show which databases will be
transferred to Active use on the next power cycle.
Figure 3-12, MFD Aux - Database Page DB Transfer
When all database updates are complete, the Database Update field at the top of the
screen will say, “Restart avionics to activate selected standby databases.” If the engines
are not running, a
Restart
softkey appears at the bottom of the MFD. Press
Restart
to
cycle power on the displays. If the Restart softkey is not present, turn
OFF
PFD1, MFD,
and PFD2.
Remove the database update card from the top slot of the MFD.
Turn
ON
the displays.
The displays may state they are verifying databases at power-up. If so, follow the on-
screen instructions to continue.
Summary of Contents for G1000 NXi