ADF/DME Failure
A DME or ADF failure is represented by the following red X’s. Refer to G1000 Wiring Diagram
and King Air 300 Series Maintenance Manual (listed in Table 1-1,) as needed.
Invalid Field
Sensor
Solutions
or
ADF
•
Ensure that GIA 63 #2 is properly functioning.
•
Reload the ADF option configurations.
•
Check for proper operation of the ADF receiver. Ensure that
the receiver is receiving power.
•
Check ADF – GIA2 interconnect.
•
For other failures of the ADF system, refer to King Air 300
Series Maintenance Manual, listed in Table 1-1.
DME
•
Ensure that GIA 63 #1 is properly functioning.
•
Reload the DME option configurations.
•
Check for proper operation of the DME receiver. Ensure that
the receiver is receiving power.
•
Check DME – GIA1 interconnect.
•
For other failures of the DME system, refer to the King Air 300
Series Maintenance Manual, listed in Table 1-1.