G1000 NXi System Maintenance Manual
Page 340
King Air 300 Series
Revision 1
190-00716-N1
7. Press the
CHK All
softkey.
8. Press the
Load
softkey
.
9. Monitor load progress. Verify software load completes without errors as indicated by the
following:
•
Green “PASS” in the Configuration and Software columns for each item loaded.
•
“Upload Complete………….COMPLETE” in the summary box.
10. Press
ENT
key on PFD1 to acknowledge upload complete.
11. Deactivate cursor.
12. Scroll to the Configuration Manager page.
13. Press the
CNFM CFG
softkey.
14. Select ok when prompted to “Confirm configuration as expected configuration”
15. Power cycle the system verify there are no red-Xs or system alerts.
16. If red-Xs or system alerts are present, troubleshoot as necessary using Section 5.