-41-
Dual Sensors:
Lamp connections on the Lamp Supply Control Board (5 VDC)
Sensor 1
Terminal
3
Lamp (Blue and Red) (+)
4
Lamp (Grey and Pink) (–)
Sensor 2
Terminal
5
Lamp (Blue and Red) (+)
6
Lamp (Grey and Pink) (–)
Wiring connections from Condor supplemental power supply to the Lamp Supply
Control Board:
Lamp Control Cable with three conductors: Orange/Yellow/Black
Interface between Messenger Module and Lamp Control Board
To External Lamp
Power Supply
Control Board
Wire color
From
Messenger
Module
9
Orange
29
10
Yellow
30
11
Black
31