Field
Description
•
"&")"
: Here, you can define whether the
current server is to be used for login authentication
to your device.
Server IP Address
Enter the IP address of the server that is to be re-
quested for login authentication.
Secret
Enter the password to be used to authenticate and, if applic-
able, encrypt data exchange between the server and
the network access server (your device). The maximum length
of the entry is 32 characters.
Priority
Assign a priority to the current server. The server
with the lowest value is the one used first for login
authentication. If this does not respond or access is denied
(only if Policy =
."&""$
), the entry with the
next-highest priority is used.
The available values are
to
, the default value is
.
Entry Active
Select whether this server is to be used for login authentication.
The function is activated by choosing
%
.
The function is activated by default.
The Advanced Settingsmenu consists of the following fields:
Fields in the Advanced Settings menu
Field
Description
Policy
Select the interpretation of the response.
Possible values:
•
."&""$
(default value): The serv-
ers are queried in order of their priority (see Priority) until a
positive response is received or a negative response is re-
ceived from an authoritative server.
•
"&""$
: A negative response to a request is ac-
cepted, i.e. a request is not sent to another server.
The device's internal user administration is is not turned off by
. It is checked after all servers have been
queried.
6 System Management