Choose the
Recovery_L
option from the update tool menu to start the iRMC
update process.
CAUTION
If the process is interrupted, the iRMC may be permanently
corrupted.
▶
Do not interrupt the iRMC upgrade process after it has started.
If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
▶
Shut down the server by pressing the power On/Off button.
▶
Disconnect the server from the mains to exit the iRMC recovery state.
5.3.2
Verifying system information backup or restore
To avoid the loss of non-default settings when replacing the system board, a
backup copy of important system configuration data is automatically stored
from the system board NVRAM to the Chassis ID EPROM. After replacing the
system board the backup data is restored from the Chassis ID board to the
new system board.
In order to verify whether the backup or restore process has been successful,
check the System Event Log (SEL), see
"Viewing and clearing the System
When using the Infrastructure Manager, please refer to the following
manuals about backup and restore function of system information.
See manual "FUJITSU Software Infrastructure Manager V2.7.0 User's
Guide", section "2.10 Backup/Restore Hardware Settings", available at:
https://ts.fujitsu.com/support/
For Japan:
See manual "FUJITSU Software Infrastructure Manager V2.7.0
解説書
",
section "2.10
ハードウェア設定バックアップ/リストア機能
", available at:
Basic software procedures
78
Upgrade and Maintenance Manual
TX1320 M5
Summary of Contents for PRIMERGY TX1320 M5
Page 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Page 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Page 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Page 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Page 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Page 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Page 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Page 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Page 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...