Preliminary steps
▶
If the HDD to be removed is combined into a RAID array, proceed as
follows:
RAID level
Procedure
RAID 0
CAUTION
RAID 0 provides no data redundancy.
In case of an HDD/SSD module is defect,
all data are lost!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID
5 array will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or
larger capacity.
After replacing the HDD module, RAID
rebuild will be performed as a background
process, see
In order to permanently remove an operational HDD that is part of a RAID
array from the server, you first need to delete the array using ServerView RAID
Manager.
CAUTION
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array!
▶
Be sure to back up your data before deleting a RAID array.
▶
For more information, see the "ServerView Suite RAID
Management" user guide.
▶
"Shutting down the server" on page 45
▶
"Getting access to the component" on page 48
Hard disk drive (HDD) / solid state drive (SSD)
144
Upgrade and Maintenance Manual
TX1320 M5
Summary of Contents for PRIMERGY TX1320 M5
Page 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Page 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Page 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Page 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Page 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Page 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Page 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Page 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Page 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...