4.12.4 Installing the HDD fan module (2.5-inch HDD
variant)
Figure 25: Installing the HDD fan module
▶
Install the HDD fan module onto the HDD cage until the locking latch snaps
in place (see circle).
▶
Ensure that the fans freely rotate.
▶
Connect the fan cable of HDD fan module 1 to the system board connector
"FAN4 SYS".
▶
Connect the fan cable of HDD fan module 2 to the system board connector
"FAN2 SYS".
Basic hardware procedures
68
Upgrade and Maintenance Manual
TX1320 M5