CAUTION
For that reason the front panel and system board must not be replaced
simultaneously! In this case, restoring the system configuration data on
the system board would fail.
When replacing the front panel, the system information like server name and
model, housing type, serial number and manufacturing data are not restored
automatically. So never forget to restore it manually by Chassis ID Prom Tool.
Preliminary steps
▶
"Locating the defective server" on page 43
.
▶
"Suspending BitLocker functionality" on page 71
.
▶
"Shutting down the server" on page 45
▶
"Disconnecting the power cord" on page 46
▶
"Getting access to the component" on page 48
Removing the defective front panel module
Figure 169: Removing the front panel module (A)
Front panel
268
Upgrade and Maintenance Manual
TX1320 M5