Removing the defective 2.5-inch HDD/SSD module
▶
Remove the HDD/SSD module, see
.
▶
If applicable, remove the HDD/SSD from the installation frame, see
"Handling HDDs or SSDs without installation frame" on page 135
.
Installing the new 2.5-inch HDD module
▶
If applicable, install the HDD/SSD in the installation frame, see
HDDs or SSDs without installation frame" on page 135
.
▶
Install the HDD/SSD module, see
"Installing 2.5-inch HDD/SSD modules"
.
Concluding steps
▶
If the HDD/SSD is configured using a RAID controller with a RAID level
higher than "0", the rebuild will start automatically, see
▶
7.5.7
Replacing a 2.5-inch backplane
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
If a PCIe backplane should be installed, remove the HDD backplane
from the first place and install it as the second backplane. The PCIe
backplane is always installed as the first backplane.
The HDD backplane is mounted on the HDD cage. It is not necessary to
remove the HDD cage before installing or removing the HDD backplane.
Hard disk drive (HDD) / solid state drive (SSD)
TX1320 M5
Upgrade and Maintenance Manual
159
Summary of Contents for PRIMERGY TX1320 M5
Page 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Page 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Page 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Page 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Page 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Page 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Page 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Page 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Page 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...