Preliminary steps
▶
"Locating the defective server" on page 43
.
▶
"Shutting down the server" on page 45
▶
"Disconnecting the power cord" on page 46
▶
"Getting access to the component" on page 48
Removing the defective heat sink
▶
"Removing the standard heat sink" on page 231
"Removing the performance heat sink" on page 232
▶
Remove the residual thermal paste from the CPU surface.
▶
Clean the CPU surface using a lint-free cloth.
Installing the new heat sink
▶
Remove the protective cover on the underside of the new heat sink.
CAUTION
▶
Do not touch the thermal paste on the underside of the heat sink.
▶
Install the heat sink, see
"Installing the standard heat sink" on page 239
or
"Installing the performance heat sink" on page 242
.
Concluding steps
▶
.
▶
"Connecting the power cord" on page 57
.
▶
"Switching on the server" on page 60
.
▶
"Performing a fan test" on page 100
.
Processor (CPU)
244
Upgrade and Maintenance Manual
TX1320 M5
Summary of Contents for PRIMERGY TX1320 M5
Page 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Page 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Page 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Page 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Page 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Page 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Page 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Page 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Page 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...