6.3
Standard power supply
6.3.1
Replacing the standard PSU
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
You are advised to perform this routine with the server in a horizontal
position.
▶
"Locating the defective server" on page 43
▶
"Suspending BitLocker functionality" on page 71
.
▶
"Shutting down the server" on page 45
.
▶
"Disconnecting the power cord" on page 46
.
▶
"Getting access to the component" on page 48
Power supply unit (PSU)
TX1320 M5
Upgrade and Maintenance Manual
103
Summary of Contents for PRIMERGY TX1320 M5
Page 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Page 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Page 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Page 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Page 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Page 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Page 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Page 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Page 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...