Jumper
Status
Description
JP1/JP2
Default (place to keep the jumper)
Password
Clear (JP1)
Password Clear enabled
Recovery
BIOS (JP2)
Recovery BIOS enabled
JP3
BIOS WP
Default
BIOS Flash Write Protect enabled
18.5
Minimum startup configuration
Field Replaceable Units
(FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
Notes and reference
System board
no TPM, expansion cards, or M.2 SSD installed
1 CPU with CPU heat
sink
no fan (disconnect fan cable)
1 memory module
installed in DIMM slot 1A
Front panel module
1 PSU
Standard PSU or hot-plug PSU installed in bay
PSU 1
Table 5: Minimum startup configuration - components
Appendix A
TX1320 M5
Upgrade and Maintenance Manual
373
Summary of Contents for PRIMERGY TX1320 M5
Page 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Page 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Page 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Page 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Page 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Page 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Page 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Page 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Page 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...