Tools:
a pair of side-cutting pliers
Preliminary steps
▶
"Locating the defective server" on page 43
.
▶
"Shutting down the server" on page 45
▶
"Disconnecting the power cord" on page 46
▶
"Getting access to the component" on page 48
Replacing the microSD card
▶
Remove the Dual microSD 64GB Enterprise, see
microSD 64GB Enterprise" on page 332
▶
Remove the defective microSD card from the Dual microSD 64GB
Enterprise.
Proceed as described in the following:
▶
To eject the defective microSD card, gently push it in and then let go, see
▶
Pull the microSD card straight out of its slot.
CAUTION
(not valid for Europe, Middle East, India and Africa)
The microSD card contains customer information.
▶
After removing the microSD card, hand the card over to the
customer.
▶
If the customer requests disposal of the defective microSD
card, proceed as follows: Using a pair of side-cutting pliers,
cut the microSD card in half.
▶
Install the new microSD card on the Dual microSD 64GB Enterprise.
Proceed as described in the following:
▶
With the label facing up, insert the microSD card into the microSD slot on
the controller until it locks in place (see
System board and components
336
Upgrade and Maintenance Manual
TX1320 M5
Summary of Contents for PRIMERGY TX1320 M5
Page 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Page 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Page 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Page 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Page 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Page 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Page 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Page 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Page 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...