CAUTION
The server automatically adjusts to a mains voltage in the range from
100 V - 240 V.
▶
You may only operate the server if its rated voltage range
corresponds to the local mains voltage.
PSU configuration (hot-plug PSUs)
PSU 1
PSU 2
Figure 28: PSU bays
PSU type
Power
PSU
500 W
AC PSU Platinum
Assembly rules
–
Always install a dummy cover into an unused PSU bay to comply with
applicable EMC regulations and satisfy cooling requirements.
–
For a redundant power supply configuration you need always two PSUs with
the same power class.
Power supply unit (PSU)
102
Upgrade and Maintenance Manual
TX1320 M5