1. MODEL SELECTION PROCEDURE
Selection of indoor units
See 2-2.MODEL LINE UP (INDOOR UNIT) and
3-1. SELECTION PROCEDURE OF INDOOR UNIT AND
OUTDOOR UNIT
See 2-3.MODEL LINE UP (OPTIONAL PARTS)
See 2-3.MODEL LINE UP (OPTIONAL PARTS)
See 2-1.MODEL LINE UP (OUTDOOR UNIT) and
3-1. SELECTION PROCEDURE OF INDOOR UNIT AND
OUTDOOR UNIT
Selection of required optional parts
●
Cassette grille for all Cassette type
●
EV kit for AS
E004-009,12,14 and AG
E004-014
Selection of controller units
●
System Controller
●
System Controller Lite
●
Touch Panel Controller
●
Central Remote Controller
●
Group Remote Controller
●
Wired Remote Controller
●
Simple Remote Controller (with operation mode)
●
Simple Remote Controller (without operation mode)
●
Wireless Remote Controller
Selection of adaptor / convertor
●
Network Convertor
●
Network Convertor for L
ON
W
ORKS
®
●
KNX Convertor for VRF
●
KNX Convertor for INDOOR UNIT
●
Modbus® Convertor for VRF
●
Modbus® Convertor for INDOOR UNIT
●
BACnet® Gateway
●
Wireless LAN adapter
●
Signal Amplifier
●
External Switch Controller
Selection of branch kit
●
Separation Tube
●
Header
END
Selection of other optional parts
●
Flange (square)
●
Flange (round)
●
Long-Life Filter
●
IR Receiver Unit
●
Remote Sensor Unit
●
Drain Pump Unit
●
Air Outlet Shutter Plate
●
Panel Spacer
●
Wide Panel
●
Half concealed kit
●
Insulation Kit for High humidity
●
Fresh air intake kit
●
Auto louver grille kit
Selection of outdoor unit
See 2-3.MODEL LINE UP (OPTIONAL PARTS)
See 2-3.MODEL LINE UP (OPTIONAL PARTS)
See 2-3.MODEL LINE UP (OPTIONAL PARTS)
- (02 - 01) -
MOD
EL
SE
LE
C
TI
O
N
MOD
EL
SE
LE
C
TI
O
N
Summary of Contents for AB* A12GATH
Page 1: ...DESIGN TECHNICAL MANUAL ...
Page 3: ...1 GENERAL INFORMATION DTV_J3LE050E_03 CHAPTER01 2017 10 31 ...
Page 20: ...2 MODEL SELECTION DTV_J3LE050E_03 CHAPTER02 2017 10 31 ...
Page 115: ...3 OUTDOOR UNITS DTV_J3LE050E_02 CHAPTER03 2017 07 21 ...
Page 119: ... Unit mm Detail B Detail A Detail C 03 03 OUTDOOR UNITS OUTDOOR UNITS ...
Page 128: ...5 WIRING DIAGRAM MODELS AJ 072LELAH AJ 090LELAH 03 12 OUTDOOR UNITS OUTDOOR UNITS ...
Page 129: ... MODEL AJ 108LELAH 03 13 OUTDOOR UNITS OUTDOOR UNITS ...
Page 133: ... SOUND LEVEL CHECK POINT Microphone Airflow 1 m 03 17 OUTDOOR UNITS OUTDOOR UNITS ...
Page 136: ...4 INDOOR UNITS DTV_VR2E018E_14 CHAPTER04 2017 10 31 ...
Page 216: ... Unit mm INSTALLATION PLACE 04 77 INDOOR UNITS INDOOR UNITS ...
Page 233: ... MODELS ARXC72GBTH ARXC90GBTH ARXC96GATH 04 94 INDOOR UNITS INDOOR UNITS ...
Page 234: ...4 9 LARGE AIRFLOW DUCT TYPE MODEL ARXN018GLBH 04 95 INDOOR UNITS INDOOR UNITS ...
Page 235: ... MODELS ARXN024GTBH ARXN030GTBH 04 96 INDOOR UNITS INDOOR UNITS ...
Page 242: ... MODELS AS A012GCAH AS A014GCAH 04 103 INDOOR UNITS INDOOR UNITS ...
Page 245: ... MODELS AS A030GTAH AS A034GTAH 04 106 INDOOR UNITS INDOOR UNITS ...
Page 247: ... MODELS AS E012GCAH AS E014GCAH 04 108 INDOOR UNITS INDOOR UNITS ...
Page 466: ...5 CONTROL SYSTEM DTV_VR2E018E_12 CHAPTER05 2017 10 31 ...
Page 690: ...6 SYSTEM DESIGN DTV_J3LE050E_03 CHAPTER06 2017 10 31 ...
Page 779: ...7 FUNCTION SETTING DTV_VR2E018E_14 CHAPTER07 2017 10 31 ...
Page 975: ...8 EXTERNAL INPUT OUTPUT DTV_VR2E018E_11 CHAPTER08 2017 10 31 ...
Page 1016: ...9 NOTES DTV_VR2E018E_11 CHAPTER09 2017 07 21 ...
Page 1034: ...10 OPTIONAL PARTS DTV_VR2E018E_13 CHAPTER10 2017 10 31 ...
Page 1068: ... 10 33 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX04BH Unit mm ...
Page 1073: ... 10 38 OPTIONAL PARTS OPTIONAL PARTS 5 5 WIRING DIAGRAMS MODEL UTP RX01AH MODEL UTP RX01BH ...
Page 1074: ... 10 39 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX01CH ...
Page 1075: ... 10 40 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX04BH ...