2-2. OUTDOOR UNIT INSTALLATION PRECAUTIONS
Note: The information listed below are general precautions. Some models also include items
that do not apply.
z
PLACES WHERE USE PROHIBITED
●
Places where there is the danger of combustible gas leakage
●
Places where sulfur gas, chlorine gas, acid, alkali, or other matter which effects equipment is generated
●
Places not affected by heat radiation from other heat sources
●
Places where the air is not stagnant
●
Places where machinery which generates high frequencies is used
●
Ocean beaches and other areas where there is a lot of salt
●
Installation in vehicles, ships, and other conveyances
●
Factory, etc. where voltage fluctuations are large
z
POINTS TO REMEMBER WHEN INSTALLING
1) The set shall be installed at a place which can withstand the weight and vibration of the
outdoor unit
2) To allow maintenance after refrigerant piping, drain piping, and electric wiring connection and
installation, provide an installation service space.
*Installation service space is shown on "3-3.INSTALLATION SPACE"
3) Be careful when installing the set at the following places.
[Installation precautions]
Contents
Countermeasures (Reference)
When installed
near adjacent
houses
Perform installation work so that operating
sound does not disturb the neighbors.
1) Install a soundproof barrier
2) Change the installation site
When there is
the possibility
of strong wind
1) If the outdoor unit is exposed to strong
wind, capacity may drop, frost may form
during heating, and operation may be
stopped by high pressure rise. In addition,
when a very strong wind blows, the fan
may be damaged.
2) When a very strong wind blows, there is
the possibility of the outdoor unit being
toppled over if held only by foundation
bolts
1) Install with the outlet side
keep a sufficient distance
away from a facing wall or
fence.
2) Make the outlet direction
and wind direction
perpendicular.
3) Fasten the outdoor unit
using toppling prevention
hardware (procured at the
site).
When snow
accumulates
If the outdoor unit is covered by accumulated
snow, it may not be able to operate.
1) Make the foundation as
high as possible.
2) Perform snow prevention
work.
When
installing the
inverter type
It may generate noise in TV sets, stereos and
PCs.
1) The inverter type should
beinstalled at a sufficient
distance from these
equipments.
- (09 - 07) -
N
O
TE
S
N
O
TE
S
Summary of Contents for AB* A12GATH
Page 1: ...DESIGN TECHNICAL MANUAL ...
Page 3: ...1 GENERAL INFORMATION DTV_J3LE050E_03 CHAPTER01 2017 10 31 ...
Page 20: ...2 MODEL SELECTION DTV_J3LE050E_03 CHAPTER02 2017 10 31 ...
Page 115: ...3 OUTDOOR UNITS DTV_J3LE050E_02 CHAPTER03 2017 07 21 ...
Page 119: ... Unit mm Detail B Detail A Detail C 03 03 OUTDOOR UNITS OUTDOOR UNITS ...
Page 128: ...5 WIRING DIAGRAM MODELS AJ 072LELAH AJ 090LELAH 03 12 OUTDOOR UNITS OUTDOOR UNITS ...
Page 129: ... MODEL AJ 108LELAH 03 13 OUTDOOR UNITS OUTDOOR UNITS ...
Page 133: ... SOUND LEVEL CHECK POINT Microphone Airflow 1 m 03 17 OUTDOOR UNITS OUTDOOR UNITS ...
Page 136: ...4 INDOOR UNITS DTV_VR2E018E_14 CHAPTER04 2017 10 31 ...
Page 216: ... Unit mm INSTALLATION PLACE 04 77 INDOOR UNITS INDOOR UNITS ...
Page 233: ... MODELS ARXC72GBTH ARXC90GBTH ARXC96GATH 04 94 INDOOR UNITS INDOOR UNITS ...
Page 234: ...4 9 LARGE AIRFLOW DUCT TYPE MODEL ARXN018GLBH 04 95 INDOOR UNITS INDOOR UNITS ...
Page 235: ... MODELS ARXN024GTBH ARXN030GTBH 04 96 INDOOR UNITS INDOOR UNITS ...
Page 242: ... MODELS AS A012GCAH AS A014GCAH 04 103 INDOOR UNITS INDOOR UNITS ...
Page 245: ... MODELS AS A030GTAH AS A034GTAH 04 106 INDOOR UNITS INDOOR UNITS ...
Page 247: ... MODELS AS E012GCAH AS E014GCAH 04 108 INDOOR UNITS INDOOR UNITS ...
Page 466: ...5 CONTROL SYSTEM DTV_VR2E018E_12 CHAPTER05 2017 10 31 ...
Page 690: ...6 SYSTEM DESIGN DTV_J3LE050E_03 CHAPTER06 2017 10 31 ...
Page 779: ...7 FUNCTION SETTING DTV_VR2E018E_14 CHAPTER07 2017 10 31 ...
Page 975: ...8 EXTERNAL INPUT OUTPUT DTV_VR2E018E_11 CHAPTER08 2017 10 31 ...
Page 1016: ...9 NOTES DTV_VR2E018E_11 CHAPTER09 2017 07 21 ...
Page 1034: ...10 OPTIONAL PARTS DTV_VR2E018E_13 CHAPTER10 2017 10 31 ...
Page 1068: ... 10 33 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX04BH Unit mm ...
Page 1073: ... 10 38 OPTIONAL PARTS OPTIONAL PARTS 5 5 WIRING DIAGRAMS MODEL UTP RX01AH MODEL UTP RX01BH ...
Page 1074: ... 10 39 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX01CH ...
Page 1075: ... 10 40 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX04BH ...