INDOOR UNIT
For the air conditioner to operate satisfactorily, install it as outlines in installation manual.
z
Indoor unit mounting position
●
Decide the mounting position with the customer
●
Install the unit level on a strong wall, floor, ceiling which is not subject to vibration.
●
The inlet and outlet ports should not be obstructed. The air should be able to blow all over the room.
●
Install the unit where the connection pipe can be easily installed.
●
Install the unit where the drain pipe can be easily installed.
●
Take servicing, etc. into consideration and leave the spaces. Also install the unit where the filter can be
removed.
●
Install the unit where satisfy the pipe length and hight.
z
Indoor unit mounting limitation
●
Install at a place that can withstand the weight of the indoor unit and install positively so that the unit will not
topple or fall.
●
Do not install the unit where there is the danger of combustible gas leakage.
●
Do not install the unit near heat sources and the location with high temperature.
●
Mount with the lowest moving parts at least 2.4m above floor or grade level.
●
Do not install the unit near a source of heat, steam, or flammable gas.
●
Do not use the unit for air conditioning or saving precision instrument, food, art, plants and animal as special
place.
●
If children may approach the unit, take preventive measures so that they cannot reach the unit.
●
Do not install where there is oily smoke, machine oil (i.e. factory), salty environment with direct sea breeze, and
too much of dust.
●
Install the unit where drainage does not cause any trouble.
●
Welding parts may be fretted if the unit is installed where corrosive gas such as sulphurous acid gas is
generated.
●
Control may not operate correctly if the unit is installed near machinery which emit electromagnetic wave.
●
Install the unit in a well-ventilated place avoiding rains and direct sunlight.
●
Install the unit where air from the outlet and noise do not disturb the neighbour.
●
Install the indoor and outdoor units, power wiring, signal wiring and remote control wiring 1 m away from
television and radio to avoid distorted images and noise. (However, distorted noise may not be avoidable even
if units and wiring mentioned above are installed 1m away from television and radio depending on conditions of
electromagnetic disturbance.)
●
When installing an indoor unit in a small room, a countermeasure must be taken to keep refrigerant concentration
limitations will never be exceeded even if there is a refrigerant leak.
●
A sound might be heard from the indoor unit such as a refrigerant flowing sound. For using in small and quiet
room such as bed room or hotel guest room, select the unit which has not exposed inside the room (Ex. Duct
type) or the unit which connects EV kit separately (Ex. wall mounted type (EEV external model) + EV kit).
- (06 - 11) -
SY
ST
EM
DE
SIGN
SY
ST
EM
DE
SIGN
Summary of Contents for AB* A12GATH
Page 1: ...DESIGN TECHNICAL MANUAL ...
Page 3: ...1 GENERAL INFORMATION DTV_J3LE050E_03 CHAPTER01 2017 10 31 ...
Page 20: ...2 MODEL SELECTION DTV_J3LE050E_03 CHAPTER02 2017 10 31 ...
Page 115: ...3 OUTDOOR UNITS DTV_J3LE050E_02 CHAPTER03 2017 07 21 ...
Page 119: ... Unit mm Detail B Detail A Detail C 03 03 OUTDOOR UNITS OUTDOOR UNITS ...
Page 128: ...5 WIRING DIAGRAM MODELS AJ 072LELAH AJ 090LELAH 03 12 OUTDOOR UNITS OUTDOOR UNITS ...
Page 129: ... MODEL AJ 108LELAH 03 13 OUTDOOR UNITS OUTDOOR UNITS ...
Page 133: ... SOUND LEVEL CHECK POINT Microphone Airflow 1 m 03 17 OUTDOOR UNITS OUTDOOR UNITS ...
Page 136: ...4 INDOOR UNITS DTV_VR2E018E_14 CHAPTER04 2017 10 31 ...
Page 216: ... Unit mm INSTALLATION PLACE 04 77 INDOOR UNITS INDOOR UNITS ...
Page 233: ... MODELS ARXC72GBTH ARXC90GBTH ARXC96GATH 04 94 INDOOR UNITS INDOOR UNITS ...
Page 234: ...4 9 LARGE AIRFLOW DUCT TYPE MODEL ARXN018GLBH 04 95 INDOOR UNITS INDOOR UNITS ...
Page 235: ... MODELS ARXN024GTBH ARXN030GTBH 04 96 INDOOR UNITS INDOOR UNITS ...
Page 242: ... MODELS AS A012GCAH AS A014GCAH 04 103 INDOOR UNITS INDOOR UNITS ...
Page 245: ... MODELS AS A030GTAH AS A034GTAH 04 106 INDOOR UNITS INDOOR UNITS ...
Page 247: ... MODELS AS E012GCAH AS E014GCAH 04 108 INDOOR UNITS INDOOR UNITS ...
Page 466: ...5 CONTROL SYSTEM DTV_VR2E018E_12 CHAPTER05 2017 10 31 ...
Page 690: ...6 SYSTEM DESIGN DTV_J3LE050E_03 CHAPTER06 2017 10 31 ...
Page 779: ...7 FUNCTION SETTING DTV_VR2E018E_14 CHAPTER07 2017 10 31 ...
Page 975: ...8 EXTERNAL INPUT OUTPUT DTV_VR2E018E_11 CHAPTER08 2017 10 31 ...
Page 1016: ...9 NOTES DTV_VR2E018E_11 CHAPTER09 2017 07 21 ...
Page 1034: ...10 OPTIONAL PARTS DTV_VR2E018E_13 CHAPTER10 2017 10 31 ...
Page 1068: ... 10 33 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX04BH Unit mm ...
Page 1073: ... 10 38 OPTIONAL PARTS OPTIONAL PARTS 5 5 WIRING DIAGRAMS MODEL UTP RX01AH MODEL UTP RX01BH ...
Page 1074: ... 10 39 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX01CH ...
Page 1075: ... 10 40 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX04BH ...