NOTES ON ENERGY SAVING FUNCTION
Energy saving function precautions and scope of guarantee
The effect of the energy saving function depends on the units used, usage environment,
installation environment, and so forth. Each energy saving function is not guaranteed to display
a fixed effect and function for operation by specific setting. Reading and understanding the
following precautions is requested before using the function.
(1) How to use the energy saving function
Since the effect of the energy saving function depends on the units used, usage
environment, installation environment, and so forth, a different effect may appear according
to the building and operating period even when operated with the same settings and
schedule. Try to gain an understanding of the features of each energy saving function and
confirm the actual effect through operation and apply appropriate settings, etc. as required.
(2) Target electric power of peak cut function
These are values used as target values when performing peak cut control. These values
do not always guarantee that the consumed power is within the target value. For example,
even if forced thermostat off and outdoor unit stoppage are activated, the control become
ineffective if the outdoor unit is performing a protective operation (oil recovery and
defrosting). As a result, the electric power consumed may exceed the target electric power.
(3) Relationship between unit protection and energy saving function
For VRF, there are operations and restrictions for protecting units. The energy saving
function operates within the range of these protective operations and restrictions. When
the energy saving function performs control against these protective operations and
restrictions, the protective operations and restrictions have priority and the energy saving
function is either restricted or may not operate. As protective operations of units, there
are oil recovery, defrosting, etc. which are automatically performed periodically or under
specified conditions.
(4) Failure, etc.
An energy saving function operates only when the related units are operating normally.
When the power of the electricity meter and the outdoor units connected to an electricity
meter and the SYSTEM CONTROLLER is turned off due to a failure, etc. the energy saving
function will not operate normally.
(5) Explaining to the building tenants
During energy saving function operation, control from the remote controller may be
overrided by the energy saving control. For this reason, it is recommended that the building
tenants be informed of this beforehand.
- (07-174) -
F
UN
C
TI
O
N
SE
T
TI
N
G
F
UN
C
TI
O
N
SE
T
TI
N
G
Summary of Contents for AB* A12GATH
Page 1: ...DESIGN TECHNICAL MANUAL ...
Page 3: ...1 GENERAL INFORMATION DTV_J3LE050E_03 CHAPTER01 2017 10 31 ...
Page 20: ...2 MODEL SELECTION DTV_J3LE050E_03 CHAPTER02 2017 10 31 ...
Page 115: ...3 OUTDOOR UNITS DTV_J3LE050E_02 CHAPTER03 2017 07 21 ...
Page 119: ... Unit mm Detail B Detail A Detail C 03 03 OUTDOOR UNITS OUTDOOR UNITS ...
Page 128: ...5 WIRING DIAGRAM MODELS AJ 072LELAH AJ 090LELAH 03 12 OUTDOOR UNITS OUTDOOR UNITS ...
Page 129: ... MODEL AJ 108LELAH 03 13 OUTDOOR UNITS OUTDOOR UNITS ...
Page 133: ... SOUND LEVEL CHECK POINT Microphone Airflow 1 m 03 17 OUTDOOR UNITS OUTDOOR UNITS ...
Page 136: ...4 INDOOR UNITS DTV_VR2E018E_14 CHAPTER04 2017 10 31 ...
Page 216: ... Unit mm INSTALLATION PLACE 04 77 INDOOR UNITS INDOOR UNITS ...
Page 233: ... MODELS ARXC72GBTH ARXC90GBTH ARXC96GATH 04 94 INDOOR UNITS INDOOR UNITS ...
Page 234: ...4 9 LARGE AIRFLOW DUCT TYPE MODEL ARXN018GLBH 04 95 INDOOR UNITS INDOOR UNITS ...
Page 235: ... MODELS ARXN024GTBH ARXN030GTBH 04 96 INDOOR UNITS INDOOR UNITS ...
Page 242: ... MODELS AS A012GCAH AS A014GCAH 04 103 INDOOR UNITS INDOOR UNITS ...
Page 245: ... MODELS AS A030GTAH AS A034GTAH 04 106 INDOOR UNITS INDOOR UNITS ...
Page 247: ... MODELS AS E012GCAH AS E014GCAH 04 108 INDOOR UNITS INDOOR UNITS ...
Page 466: ...5 CONTROL SYSTEM DTV_VR2E018E_12 CHAPTER05 2017 10 31 ...
Page 690: ...6 SYSTEM DESIGN DTV_J3LE050E_03 CHAPTER06 2017 10 31 ...
Page 779: ...7 FUNCTION SETTING DTV_VR2E018E_14 CHAPTER07 2017 10 31 ...
Page 975: ...8 EXTERNAL INPUT OUTPUT DTV_VR2E018E_11 CHAPTER08 2017 10 31 ...
Page 1016: ...9 NOTES DTV_VR2E018E_11 CHAPTER09 2017 07 21 ...
Page 1034: ...10 OPTIONAL PARTS DTV_VR2E018E_13 CHAPTER10 2017 10 31 ...
Page 1068: ... 10 33 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX04BH Unit mm ...
Page 1073: ... 10 38 OPTIONAL PARTS OPTIONAL PARTS 5 5 WIRING DIAGRAMS MODEL UTP RX01AH MODEL UTP RX01BH ...
Page 1074: ... 10 39 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX01CH ...
Page 1075: ... 10 40 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX04BH ...