![Fuji Electric FRENIC-VG Series User Manual Download Page 318](http://html1.mh-extra.com/html/fuji-electric/frenic-vg-series/frenic-vg-series_user-manual_2341868318.webp)
6-242
6.13.4 Function
codes
• A dangerous condition may result if a mistake is made in function code data. Check the data again after the
data is set and entered.
Otherwise, an accident could occur.
• The keypad will not display any optional function codes of the optional AIO expansion card (i.e., E51, E52,
E55, E56, E59, E60, E63, E64, E67, E68, E72, E73, E77, E78, E82, E83, E103, E104, E107, or E108) unless
the optional AIO expansion card is mounted. These optional function codes will be displayed only after the
optional expansion card is mounted.
Function codes E51, E52, E55, E56, E59, E60, E63, E64, E67, E68, E72, E73, E77, E78, E82, E83, E103,
E104, E107, and E108 will be operable with this optional expansion card mounted.
The keypad will display these function codes with the optional AIO expansion card mounted. Otherwise,
the keypad will not display the functions.
Table 6.13.3
Parameter name
No.
Name Keypad
display
Setting range
Description
E51
Ai3 function selection
Ai3 FUNC
0-27
E52
Ai4 function selection
Ai4 FUNC
0-27
E55
Ai3 gain setting
GAIN Ai3
-10.000-10.000 (times)
E56
Ai4 gain setting
GAIN Ai4
-10.000-10.000 (times)
E59
Ai3 bias setting
BIAS Ai3
-100.0-100.0(%)
E60
Ai4 bias setting
BIAS Ai4
-100.0-100.0(%)
E63
Ai3 filter setting
FILTER Ai3
0.000-0.500(s)
E64
Ai4 filter setting
FILTER Ai4
0.000-0.500(s)
E67
Increment/decrement
limiter (Ai3)
A/D-L-Ai3 0.00-60.00(s)
E68
Increment/decrement
limiter (Ai4)
A/D-L-Ai4 0.00-60.00(s)
E72
AO4 function selection
AO4 FUNC
0-40
E73
AO5 function selection
AO5 FUNC
0-40
E77
AO4 gain setting
GAIN AO4
-100.00-100.00 (times)
E78
AO5 gain setting
GAIN AO5
-100.00-100.00 (times)
E82
AO4 bias setting
BIAS AO4
-100.0-100.0(%)
E83
AO5 bias setting
BIAS AO5
-100.0-100.0(%)
E84
AO1-5 filter setting
FILT AO1-5
0.000-0.500(s)
E103
Ai3 offset
Ai3 OFSET
-100.00-100.00(%)
E104
Ai4 offset
Ai4 OFSET
-100.00-100.00(%)
E107
Ai3 dead zone
Ai3 BLIND
0.00-10.00(%)
E108
Ai4 dead zone
Ai4 BLIND
0.00-10.00(%)
See Chapter 4.
Summary of Contents for FRENIC-VG Series
Page 1: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...
Page 2: ......
Page 3: ...High Performance Vector Control Inverter User s Manual Option Edition ...
Page 155: ...6 5 SX Bus Interface Card 6 79 Chap 6 CONTROL OPTIONS Figure 6 5 5 ...
Page 156: ...6 80 Basic Connection Diagram Figure 6 5 6 ...
Page 344: ......
Page 346: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...