6-184
Address Signal
name
Description
Remarks
RWwn+10 Response code 2
Turning the RYnF ON stores the response code (Table 6.7.26)
corresponding to the command code specified in RWwn+10,
12, 14, 16, and 18. If the command code has normally been
executed, zero (0) is automatically written; if any error has
occurred during processing of the command code, any value
other than zero is written.
Enabled with 8X setting
RWwn+11 Read data 2
If the command code specified in RWw10, 12, 14, 16, or 18 has
normally been executed, the response data for that command
code is automatically written.
RWwn+12 Response code 3
Same as command code 2
RWwn+13 Read data 3
Same as write data 2
RWwn+14 Response code 4
Same as command code 2
RWwn+15 Read data 4
Same as write data 2
RWwn+16 Response code 5
Same as command code 2
RWwn+17 Read data 5
Same as write data 2
RWwn+18 Response code 6
Same as command code 2
RWwn+19 Read data 6
Same as write data 2
RWwn+1A
|
RWwn+1F
Not used.
-
n: Value determined by a station address
Summary of Contents for FRENIC-VG Series
Page 1: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...
Page 2: ......
Page 3: ...High Performance Vector Control Inverter User s Manual Option Edition ...
Page 155: ...6 5 SX Bus Interface Card 6 79 Chap 6 CONTROL OPTIONS Figure 6 5 5 ...
Page 156: ...6 80 Basic Connection Diagram Figure 6 5 6 ...
Page 344: ......
Page 346: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...