6.5 SX Bus Interface Card
6-105
Chap. 6
CO
NTR
O
L O
P
TIONS
5
VG DO1 (standard
+
DIOA: 13 bits)
(MSB) (LSB)
15
8 7
0
0) Y1
1) Y2
2) Y3
3) Y4
4) Y5A
5) Unused
6) Unused
7) Unused
8) Y11
9) Y12
10) Y13
11) Y14
12) Y15
13) Y16
14) Y17
15) Y18
6
Acceleration time, deceleration time
(MSB)
(LSB)
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Acceleration (deceleration) time data
Acceleration
(deceleration) time data: 0.1s/1d
7
Selecting function code address and selecting function code data
(MSB)
(LSB)
15
14
1 0
Selecting function code 1 address
Selecting function code 1 data
Selecting function code 2 address
Selecting function code 2 data
"Selecting function code 1, 2 address" (16 bits each) write the link number corresponding to the
function code selected by MICREX-SX. Write the data to "Selecting function code 1, 2 data".
Note: Upon selecting, be sure to write the link number and data together.
Writing from this frame to the S code is prohibited. For a command equivalent to the S code,
give commands from each dedicated frame.
0: OFF, 1: ON
Summary of Contents for FRENIC-VG Series
Page 1: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...
Page 2: ......
Page 3: ...High Performance Vector Control Inverter User s Manual Option Edition ...
Page 155: ...6 5 SX Bus Interface Card 6 79 Chap 6 CONTROL OPTIONS Figure 6 5 5 ...
Page 156: ...6 80 Basic Connection Diagram Figure 6 5 6 ...
Page 344: ......
Page 346: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...