6.11.5 Function
codes
•
Incorrect use of function code data may result in a hazardous state. Consequently, re-check data after finishing
setting and writing data.
Risk of accident
Installation of the DI interface card allows use of function codes o01 to o04. These function codes are not
normally (when the option had not been installed) displayed on the keypad.
Table 6.11.5
Parameter name
No.
Name Keypad
display
Setting range
Setting description
o01
DIA function selection
DIA FUNC
0, 1
0: Binary
1: BCD
o02
DIB function selection
DIB FUNC
0, 1
0: Binary
1: BCD
o03
DIA BCD input setting
BCD CMND A
99 - 7999
o04
DIB BCD input setting
BCD CMND B
99 - 7999
6.11.5.1
Data latch function
DI input data is normally captured internally and applied inside the inverter every 1 ms. A data latch
function can be used when you wish to hold DI input data or reduce variation in lower bits when
capturing input from an external A/D converter.
[Setting method]
Set function codes X1 to X14 corresponding to the desired contact to 55 (DIA) or 56 (DIB) to assign data
latch operation. Then set the contact in question as follows:
On: Normal capture
Off: DI input hold (data is not captured, and the last data value before the contact was turned off)
Summary of Contents for FRENIC-VG Series
Page 1: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...
Page 2: ......
Page 3: ...High Performance Vector Control Inverter User s Manual Option Edition ...
Page 155: ...6 5 SX Bus Interface Card 6 79 Chap 6 CONTROL OPTIONS Figure 6 5 5 ...
Page 156: ...6 80 Basic Connection Diagram Figure 6 5 6 ...
Page 344: ......
Page 346: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...