6-228
(2) Combinations not mountable (operating procedure error)
The two DIO expansion cards mounted cannot be both set to DIOA. The two DIO expansion cards
mounted cannot be both set to DIOB, either. If such settings are made, operating procedure error
er6
will result.
FRENIC-VG
FRENIC-VG
Reserved
Reserved
OPC-VG1-DIO
(DIOA)
OPC-VG1-DIO
(DIOA)
OPC-VG1-DIO
(DIOB)
OPC-VG1-DIO
(DIOB)
Figure 6.12.2
6.12.2.2 Specifications
• The system will not operate normally if settings for the switches (SW1 and SW2) on the optional expansion
cards are wrong. Refer to the following settings and make correct settings.
Table 6.12.1 Hardware Specifications
Specification
Item
DIOA
DIOB (dedicated to UPAC)
Name DIO
expansion
card
Model
OPC-VG1-DIO *DIOA or DIOB is selected with SW2.
Number of
points
4 (X11-X14)
16 (X21-X36)
Ground
CM: Ground common to all the four points.
Input
Circuit
Photocoupler-insulated circuit
SW1 is used to select current sink output (SINK) or current source output (SOURCE).
Rated continuous current per circuit: Approximately 3 mA
Number of
points
8 (Y11-Y18)
10 (Y21-Y30)
Ground
CME: Ground common to both two points.
Output
Circuit
Photocoupler-insulated circuit (50 mA DC max. at 28 V max.)
Bi-directional connections possible. (SINK and SOURCE)
Power supply
24 V
Power is supplied through the PCB of the FRENIC-VG. Connect the power supply harness to
CN24 or CN25 of the FRENIC-VG.
Summary of Contents for FRENIC-VG Series
Page 1: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...
Page 2: ......
Page 3: ...High Performance Vector Control Inverter User s Manual Option Edition ...
Page 155: ...6 5 SX Bus Interface Card 6 79 Chap 6 CONTROL OPTIONS Figure 6 5 5 ...
Page 156: ...6 80 Basic Connection Diagram Figure 6 5 6 ...
Page 344: ......
Page 346: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...