![Fuji Electric FRENIC-VG Series User Manual Download Page 111](http://html1.mh-extra.com/html/fuji-electric/frenic-vg-series/frenic-vg-series_user-manual_2341868111.webp)
6.2 PG Interface Expansion Card
6-35
Chap. 6
CO
NTR
O
L O
P
TIONS
The direction of rotation for slave motors is determined by [IVS] and the pulse input format.
Table 6.2.13
(1)
(2)
(3)
IVS
Slave direction of operation
B-phase high
A-phase input
B-phase, 90° advance
OFF
Forward
B-phase high
A-phase input
B-phase, 90° advance
ON
Reverse
B-phase low
B-phase input
B-phase, 90° delay
OFF
Reverse
B-phase low
B-phase input
B-phase, 90° delay
ON
Forward
Pulse input format
(1) Command
pulse/command
code
(2) Forward run pulse/reverse run pulse
(3) Two signals with a 90° phase difference
Select the pulse input format with function code o13.
6.2.5.2
Synchronized operation method
• Manipulate the [FWD] terminal and [SYC] (the contact input terminal) simultaneously during pulse train
operation.
• When [FWD] turns on with a delay after [SYC] turns on while a pulse train continues to be input, the motor
may accelerate to its maximum speed in order to eliminate the accumulated deviations.
Risk of bodily injury
• Operating the motor with an incorrect allocation of the function selection input function code's data may result
in bodily injury or equipment damage. Re-check allocation prior to operation.
Risk of equipment damage
Synchronized operation signal [SYC]
During pulse train operation, allocate one of the contacts X1 to X14 to 27 (SYC) for the slave motor and
manipulate [SYC] together with the [FWD] signal.
Table 6.2.14
Function code
Function name
Pulse train function
E01 to E13
X1 to X14 function
selection
In order to perform position control operation, allocate the synchronized
operation instruction ([SYC]: 27) to one of the contact input terminals
listed to the left.
Summary of Contents for FRENIC-VG Series
Page 1: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...
Page 2: ......
Page 3: ...High Performance Vector Control Inverter User s Manual Option Edition ...
Page 155: ...6 5 SX Bus Interface Card 6 79 Chap 6 CONTROL OPTIONS Figure 6 5 5 ...
Page 156: ...6 80 Basic Connection Diagram Figure 6 5 6 ...
Page 344: ......
Page 346: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...