ENGLISH - 22
“OMEGA” CARD PROGRAMMING TABLE (*)
STEP DESCRIPTION MIN MAX SET
STEP
P1
Consistency hysteresis
(% set of consistency)
1 50 8
1% of set of
consistency
P2 Set
OK 50
150
120
1 consistency value
number
P3
Compressor ON in
delivery
0 1 1
0= disabled
1= enabled
P4
Amperage selection TA
2A
32A
8A
2A (AMP. Agitator in
batch freezing)
P5
Voltage selection (Hz)
0
2
0
0=400/50 1=220/60
2=220/50
P6
Compressing time ON
in delivery
0 1 1
0= 2”, 1=12”
(if P3 enabled)
P7
Alarm for lack of growth
0
1
0
0= enabled
(time-out 16 min.)
1=disabled
(time-out 35 min.)
P8
Correction selector
steps
3 21 12
1 consistency value
number
(*)
The parameters can change according to the software versions or to customising
processes. It is always possible to refer to the test card supplied with the machine.