7
APPENDIX
(Operation manual for the recorder with the Model 8346 TC/SYNC card installed)
Generator Setup
By installing the Model 8346 TC/SYNC card into the recorder, the Generator Setup functions activate
and the following features are available.
How to enter the Generator Setup mode
Setting the time code recording mode
Recording mode
Rec Run
Free Run
Ext Run
24H Run
Time code that is continuous with the time
code previously recorded will be recorded.
This mode is also useful to re-record a dis-
continuous time code.
Time code generated by the internal gen-
erator will be recorded.
External time code will be recorded.
Time code generated by the internal gen-
erator will be recorded from the current
time of the recorder's internal clock.
Function
<CAUTION>
The 8346 does not record all time code information. It
records only the ABS time at the recording start point
and the time code offset value. Therefore, if you record
discontinuous time code in the middle, it cannot recog-
nize it. Also note that because the user's bit at the re-
cording start point is maintained, the 8346 cannot rec-
ognize user's bit change in the middle.
2.
Use the Jog dial to display the desired recording
mode.
You can choose from 4 recording modes available.
<CAUTION>
When you create a new program using the program se-
lect function, the LTC with the same MTC offset (which
you can see in the “
MTC offset?
” menu of the Setup mode)
as the current program is recorded in the new program.
Therefore, if you use the same LTC with the new pro-
gram, you do not need to re-record LTC.
1. Recording/playback of external or internally generated time code
2. Force jam to external time code
3. Outputting the internally generated or recorded time code
4. Setting of the chase offset between external time code and MTC
1.
Press the [SETUP] key while holding down the
[SHIFT] key.
The recorder enters the Generator Setup mode in
which the following menus are available.
The display will show “
TC Gen.?Rec Run
” (the
default) when you first select the Generator Setup
mode. However, from the second time, the menu
selected last time will appear.
By rotating the
Jog
dial, the menus of the
Generator Setup mode appear one after the other.
1.
Select “TC Gen.? Rec Run” of the Generator Setup
mode and press the [EXECUTE/YES] key.
The recording mode currently selected starts
flashing, showing that you are now ready to select
the desired recording mode.
3.
Press the [EXECUTE/YES] key after selecting the
recording mode.
F
S
M
H
OL
0
18
12
9
6
3
kHz
FS
BIT
SF
24
OL
0
18
12
9
6
3
GEN
CLOCK
F
S
M
H
OL
0
18
12
9
6
3
kHz
FS
BIT
SF
24
OL
0
18
12
9
6
3
GEN
CLOCK
F
S
M
H
OL
0
18
12
9
6
3
kHz
FS
BIT
SF
24
OL
0
18
12
9
6
3
GEN
CLOCK
F
S
M
H
OL
0
18
12
9
6
3
kHz
FS
BIT
SF
24
OL
0
18
12
9
6
3
GEN
CLOCK
F
S
M
H
OL
0
18
12
9
6
3
kHz
FS
BIT
SF
24
OL
0
18
12
9
6
3
CHASE OFFSET
CLOCK
F
S
M
H
OL
0
18
12
9
6
3
kHz
FS
BIT
SF
24
OL
0
18
12
9
6
3
CHASE OFFSET
CLOCK
OL
0
18
12
9
6
3
kHz
FS
BIT
24
OL
0
18
12
9
6
3
CLOCK
F
S
M
H
∞
42
OL
0
30
24
18
12
9
6
3
kHz
24
FS
BIT
SF
24
∞
42
OL
0
30
24
18
12
9
6
3
GEN
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
CLOCK
INT
F
S
M
H
∞
42
OL
0
30
24
18
12
9
6
3
kHz
24
FS
BIT
SF
24
∞
42
OL
0
30
24
18
12
9
6
3
GEN
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
CLOCK
INT
Flashing
OL
0
18
12
9
6
3
kHz
FS
BIT
24
OL
0
18
12
9
6
3
GEN
CLOCK
Summary of Contents for D2424LVmk2
Page 157: ......