Status Reporting System
Description of Status Registers
2
2-9
Table 2-4. STATus:QUEStionable Register Bits
Bit No.
Description
0
QUEStionable:VOLTage Register Summary.
1
QUEStionable:CURRent Register Summary.
2 to 4
These bits are not used.
5 FREQuency.
The bit is set if frequency measurement is invalid due to poor signal quality.
6 to 14
These bits are not used.
15
This bit is always 0.
STATus:QUEStionable:CURRent Register
This register comprises information about overload/underload states that may occur if the
input current channel range is exceeded or the input signal is too low. It can be queried by
the STATus:QUEStionable:CURRent:CONDition? and
STATus:QUEStionable:CURRent[:EVENt]? commands.
Table 2-5. STATus:QUEStionable:CURRent Register Bits
Bit No.
Description
0 INPut1
OVERrange
1 INPut3
OVERrange
2 INPut5
OVERrange
3 INPut7
OVERrange
4 INPut9
OVERrange
5 INPut11
OVERrange
6 to 7
These bits are not used.
8 INPut1
UNDERrange
9 INPut3
UNDERrange
10 INPut5
UNDERrange
11 INPut7
UNDERrange
12 INPut9
UNDERrange
13 INPut11
UNDERrange
14
This bit is not used.
15
This bit is always 0.
STATus:QUEStionable:VOLTage Register
This register comprises information about overload/underload states that may occur if the
input voltage channel range is exceeded or the input signal is too low. It can be queried
by the STATus:QUEStionable:VOLTage:CONDition? and
STATus:QUEStionable:VOLTage[:EVENt]? commands.
Summary of Contents for NORMA 4000 Operators
Page 6: ...Remote Control Users Guide iv ...
Page 8: ...Remote Control Users Guide vi ...
Page 10: ...Remote Control Users Guide viii ...
Page 26: ...Remote Control Users Guide 2 2 ...
Page 38: ...Remote Control Users Guide 3 2 ...
Page 50: ...Remote Control Users Guide 4 2 ...
Page 150: ...Remote Control Users Guide 4 102 ...
Page 152: ...Remote Control Users Guide 5 2 ...
Page 160: ...Remote Control Users Guide 6 2 ...
Page 184: ...Remote Control Users Guide 6 26 ...