time-division multiple access (TDMA), or carrier sense multiple access
(CSMA) protocols.
Environmental rating
The unit is certified for outdoor usage, equipped with vibration-proof
connectors, and designed for fast installation and enhanced reliability in
harsh environments.
Product specifications
For detailed product specifications, refer to the product data sheet for the
Fluidmesh 4200 FIBER.
Transceiver and gateway unit power consumption
In service, Fluidmesh transceiver units and gateway units consume
electrical power at the rates given in the table below.
IMPORTANT
In service, transceiver and gateway units will consume power
at various levels between the quoted lower limit and upper
limit, depending on data traffic load, signal strength,
environmental conditions such as line-of-sight and atmospheric
moisture, and other factors.
Note that the power consumption of transceiver units tends to
be affected in inverse proportion to the unit temperature (in
other words, power consumption tends to rise when the
temperature of the unit falls, and the other way around).
Table 1. Power consumption figures (transceiver units)
Unit series
Minimum power
consumption
Nominal power
consumption (typical
conditions)
Maximum power
consumption
(realistic system-
design
assumption)
FM PONTE
50
4 Watts
6 to 7 Watts
10 Watts
FM 1200
VOLO
4 Watts
6 to 7 Watts
10 Watts
FM 1300
OTTO
8 Watts
10 to 12 Watts
15 Watts
FM 3200-
series
4 Watts
6 to 7 Watts
10 Watts
FM 4200-
series
4 Watts
6 to 7 Watts
10 Watts
FM 3500
ENDO
8 Watts
10 to 12 Watts
15 Watts
Fluidmesh 4200 FIBER
© Fluidmesh Networks LLC
Page 13 of 180