FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 12 of 131
3.4 The Front View and Key Functions
Figure 3.1 - Front panel view of FT-10 FILL
3.4.1 Display
The weight display of FT-10 FILL is seven segments LED. At the right side of the display there are three
LED’s for indicating the net, process steps and the unit (standard kg).
The meanings of the announcement LED’s on the display are:
Info
Announces the Total, filling capacity t/hour, Quantity or last filling value.
Announces the weight is in the centre of zero.
Announces the weight value on the display is unstable.
Net
Announces the indicated value is the net weight.
R
Announces the ready status to start filling process.
Announces the coarse/fine feedings.
Announces the end of filling.
Units
Kilogram (kg) and libre (lb) units are located on the right of the display.
3.4.2 Key Pad
The keys and the key functions of FT-10 FILL are:
Function:
Key function is programmable to Total, 1/h (ton/hour or klb/hour) indication, Quantity,
Last filling value. Refer to parameter [
116
] (Page 34
Target/Coarse/Fine Menu:
To enter the target
(nominal filling value), Coarse lead in and fine
lead,
press
shortly
this key. Refer to related mode (Page 69).
Mode Related Filling Parameters:
To enter the process parameter menu, press
long
this key.
Refer to related mode (Page 41).
Tare / Clear:
Pressing this key it tares the scale and get into the Net mode in weighing mode.
Press long time to clear the tare.
Zeroing:
In Gross mode and Ready state
, if the scale doesn’t show zero while there is no load
on the pan, you can zero the scale by pressing this key.
Reset:
If pressing this key in filling or emptying operation, process is cancelled and the
instrument returns to the Ready state.
Print:
By pressing this key weight data and other information, depending on the setup
parameters, are sent to a printer or a PC via serial port in basic weighing mode.
FT-10 Fill