![Flintec FT-10 FILL Technical Manual Download Page 102](http://html1.mh-extra.com/html/flintec/ft-10-fill/ft-10-fill_technical-manual_2305534102.webp)
FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 101 of 131
10000
16
10001
17
Target value
10010
18
Not used
10011
19
Coarse value
10100
20
Not used
10101
21
Fine value
10110
22
Label number (CN) (always integer)
10111
23
Last filling value
11000
24
Quantity (always integer )
11001
25
Total
11010
26
Inputs status always integer)
11011
27
Outputs status (always integer)
11100
28
Ton / hour indication
11101
29
Not used
11110
30
Process error messages (Refer to Table 14.1)
11111
31
Use the Expanded Command list (Refer to Table 14.3)
D32
CMD Flag
Toggles
The command is applied successfully
D31…D0
By default, Actual weight value is represented.
To represent other weight or calibration status, refer to D33~D37.
Process error messages (always 32 bit integer)
Low Dword of TxPDO 1 (T_UL1) descriptions when read command is ‘Process error messages’. Refer to
RxPDO 1 (R_UL1) of ‘PLC Output to FT-10 FILL CO Input’.
Bit Number
Low Dword of TxPDO 1 (T_UL1) Description
D31 … D16
Not in use
D15 … D8
Process
State
Bin
Dec
Process state
00000000
0
No process (Adc out, Over, Under etc.)
00000001
1
Ready
00000010
2
In filling process
00000011
3
End of filling (FULL)
00000100
4
In discharging process
D7 ... D0
Process
Warning
Messages
Bin
Dec
Messages
00000000
0
No process error
00000001
1
END
00000010
00000011
2
3
Not used
00000100
4
RESET
Process
error
Messages
10000000
128
E GATE
10000001
129
E TRNG
10000010
130
E TARE
10000011
131
E ZERO
10000100
132
E ZRNG
10000101
133
FILL t
10000110
134
E VALV
10000111
135
E HOLE
10001000
136
Not used
10001001
137
NO FEED
Table 14.1
– Process error messages