FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 80 of 131
40009
R/W
1
Control
Dec
Description
0
None
1
Zero
2
Tare
3
Clear
4
8
Start for filling
9
Reset
14
Start for emptying
40010
R/W
1
Not used
40011
R/W
2
Target value
Refer to page 69
40013
R/W
2
Not used
40015
R/W
2
Coarse value
Refer to page 69
40017
R/W
2
Fine value
Refer to page 69
40019
R/W
1
CN (Label number)
Refer to parameter [142] on page 34
40020
R
2
Last filling value
40022
R/W
1
Quantity
40023
R/W
2
Total
40025
R
1
Status of Inputs
Bit
Description
D0
Input 1
0
– Passive
1 - Active
D1
Input 2
D2
Input 3
D3
Input 4
40026
R/W
2
Digital outputs status
D0
Output 1
0
– Passive
1 - Active
D1
Output 2
D2
Output 3
D3
Output 4
D4
Output 5
D5
Output 6
D6
Output 7
D7
Output 8
40028
R/W
2
Not used
40030
R/W
1
Calibration
Dec
Description
0
None
188
Adjust Zero Calibration
220
Adjust Span Calibration
( 1 )
236
Total Load Cell Capacity
( 1 )
eCal
Coefficients
250
Average mV/V
( 1 )
171
Dead Load
( 1 )
23205
Save the coefficients of eCal
40031
R/W
2
Span Calibration Value / LC capacity / mV value / Dead load value
40033
R
1
Calibratio
n Status
De
c
Description