E GAtE
]
Feeding gate position error. Gate is not close.
[
No FEEd
]
Feeding error message appears if weight value is not increased
after feeding output is activated. Refer to parameter [
508
].
[
FıLL t
]
This prompt announces that the filling is not finished in the filling
time and is ended. Error is cancelled by Reset input. Refer to
parameter [
509
].
[
E trGt
]
The weight is less than discharging target.
Error is cancelled by Reset input.
Filling cycle:
Feeding gate will be checked continuously at discharging. If the gate is open at discharging, the discharging
will stop until feeding gate will be closed.
Digital Inputs and Outputs Connection :
I / O
Descriptions
Input 1
Start for filling
Input 2
Start for discharging
Input 3
Gate is closed (0 = Open, 1=Closed)
Input 4
Reset
Output 1
Coarse discharge
Output 2
Fine discharge
Output 3
Fill
Output 4
End of filling (Full)
Output 5
End of discharging
E
Error
Z
In zero range (refer to par. [