FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 43 of 131
Mode Related Display Messages
The messages below are shown on the display in the filling cycle or if there is any error in the filling.
Display
Operation
[
StArt
]
This message is shown on the display during Start Delay.
[
FuLL
] [ XXXXX ]
This message is shown at the end of filling. [
FuLL
] message and
the weight value are shown alternately until the container is
removed from the platform.
[
E trnG
] [ XXXXX ]
Tare range error message appears if tare of the container is not
between minimum tare and maximum tare values entered in
process parameters above. This error is acknowledged by Start
Input, if the tare goes in to the range.
[
No FEEd
]
Feeding error message appears if weight value is not increased
after feeding output is activated. Refer to parameter
[508]
[
FıLL t
]
This prompt announces that the filling is not finished in the filling
time and is ended. Error is cancelled by Reset input.
Refer to parameter [
509
].
Filling cycle
Press <
Zero
> key if the scale is not indicated zero after powered on. Apply start input after loading the scale
with the container. The filling is done as indicated below. The [
FuLL
] prompt is displayed after end of the
filling and take off the container. After loading the next container press the start input again to fill it.
Notes
1) There is a preact adjustment delay only in preact adjustment frequency (refer to parameter [503] ).
2) The fine feed output is activated together with coarse feed output if parameter [501] is 1 as indicated in
the drawing above. If this parameter is adjusted to 0, the fine feed output is activated after coarse feeding.