FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 49 of 131
Note:
For
TARGET
and
TOLERANCE
entry please see section 7, page 69
Mode Related Display Messages
The messages below are shown on the display in the filling cycle or if there is any error in the filling.
Display
Operation
[
StArt
]
This message is shown on the display during Start Delay.
[
¯ − _ − ¯ ]
Means the filling valve is going down. It disappears after the valve
goes completely down.
[
_ − ¯ − _ ]
Means the filling valve is going up. It disappears after the filling
valve goes up position.
[
FuLL
] [ XXXXX ]
This message is shown at the end of filling. [
FuLL
] message and
the weight value are shown alternately until the container is
removed from the platform.
[
E trnG
] [ XXXXX ]
Tare range error message appears if tare of the container is not
between minimum tare and maximum tare values entered in
process parameters above. This error is acknowledged by Start
Input, if the tare goes in to the range.
[
E HoLE
]
While the filling valve is going down, if the weight is bigger than
safety weight this message appears.
Reset is waited for.
[
E vALv
]
This prompt is displayed and feeding stops, if “Filling Valve is
Down” input becomes passive during feeding. Feeding starts
again after “Filling Valve is Down” input becomes “active”.
[
No FEEd
]
Feeding error message appears if weight value is not increased
after feeding output is activated. Refer to parameter
[508
].
[
FıLL t
]
This prompt announces that the filling is not finished in the filling
time and is ended. Error is cancelled by Reset input. Refer to
parameter [
509
].