
FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 21 of 131
4.3.9 EtherNet/IP Connection (only FT-10 FILL EI)
EtherNet/IP connection is done as indicated below in Figure 4.13.
Figure 4.13
– FT-10 FILL EI interface connections
EtherNet/IP Connector pin configuration (RJ45)
Pin
Signal
DIR
Description
1
TX+
Out
Differential Ethernet transmit data +
2
TX−
Out
Differential Ethernet transmit data −
3
RX+
In
Differential Ethernet receive data +
6
RX−
In
Differential Ethernet receive data −
4
Not used
Terminated
5
Not used
Terminated
7
Not used
Terminated
8
Not used
Terminated
Shield
Chassis ground
The HUB connection cabling will be a direct connection as shown below:
Figure 4.14 - HUB connection
The PC connection cabling will be done via cross cable as shown below. IP address blocks and gateway
address of FT-10FILL and PC should be the same in cross connection.
Figure 4.15 - Cross PC connection
Warning
:
Connect the shield to the reference ground or shield pin of the power connector.
Warning:
Disconnect IndFace1X PC software before starting EtherNet/IP interfacing.