6.6 Mode 6: Multicycle Packing / Bagging
Typical Applications
•
Pack / Bag filling machines for filling bags
bigger than the hopper capacity.
Operation
•
The hopper is filled up to target value
accurately as 2 speeds.
•
It is emptied totally by “bag is ready” input.
•
The following Weighing and emptying
processes goes on until reaching the target
value.
•
After filling the target weight in to the bag, the
End prompt is indicated.
Mode Related Filling Parameters
The mode related filling parameters shall be entered before start up the filling. Please enter the values
below carefully for better filling performance of the filling machine.
Display
Operation
[
123.456
kg ]
Press long
key, [
L_trGt
] message appears.
[
L_trGt ]
[ XXXXX ]
Limit target.
Maximum capacity of hopper.
Enter the hoper weighing capacity value by pressing
and
keys. Press the
key to go to the next parameter.
[
Zero_r ]
[ XXXXX ]
Zero range.
This parameter has two functions;
1. At filling start: To start feeding, the weight indication has to be
in Zero Range.
2. At Emptying: If the weigh is decreased in this range, the scale is
accepted empty and the gate is closed.
Enter zero range value by pressing
and
keys. Press the
key to go to the next parameter.
[
d_dıSC ]
[ X.X ]
End of emptying delay.
After the weight value goes into zero
range at emptying, [
d_dıSC
] parameter delays closing the gate for
completely emptying. Enter the value by pressing
and
keys. Press the
key to go to the next parameter.
Maximum value is 9.9 seconds. Default is 0.0 seconds.
[
d_GAtE ]
[ X.X ]
Gate control delay.
This parameter has two functions;
1. If there is no gate switch (GAT_Ch = 0), this time delays "End
of emptying" output.
2. If there is a gate switch (GAT_Ch = 1 ), this time delays to
check the gate position.
Enter gate control delay value by pressing
and
keys.
Press the
key to go to the next parameter.
Maximum value is 9.9 seconds. Default is 0.0 seconds.