FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 117 of 131
FT-10 FILL Output to PLC Input 2
nd
Dword
Bit Number
2
nd
Dword Description
D31 … D24
Outputs
Output bit status (Active = 1)
D23 … D16
Inputs
Input bit status (Active = 1)
D15 … D12
Error Codes
FT-10 FILL
Bin
Dec
Descriptions
0000
0
No error found
0001
1
ADC out
0010
2
ADC over
0011
3
ADC under
0100
4
System Error
0101
5
In programming mode
0110
6
Low/High Voltage Error
D11
Not in use
D10
Process Error
0
No error
1
Process error (Check the ‘Process error messages)
D9
Not in use
D8
Centre of zero
0
Weight is in out of zero range
1
Weight is in zero range
D7
Indication
0
Gross
1
Net
D6
MD
– Motion
Detection
0
Stable
1
Dynamic
D5 … D1
Read
Command
Response
00000
0
Actual weight (Net if the indication is in Net)
00001
1
Gross weight
00010
2
Tare weight
00011
3
Calibration Status (Refer to
Fehler! Verweisquelle k
onnte nicht gefunden werden.
)
00100
10000
4
16
Not used
10001
17
Target value
10010
18
Not used
10011
19
Coarse value
10100
20
Not used
10101
21
Fine value
10110
22
Label number (CN) (always integer)
10111
23
Last filling value
11000
24
Quantity (always integer)
11001
25
Total
11010
26
Inputs status (always integer)
11011
27
Outputs status (always integer)
11100
28
Ton / hour indication
11101
29
Not used
11110
30
Process error messages (Refer to
Fehler! Verweisquelle k
onnte nicht gefunden werden.
)
11111
31
Use the Expanded Command list
(Refer to
Fehler! Verweisquelle konnte nicht gefunden w
erden.
)
D0
CMD Flag
Toggles
The command is applied successfully