FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 7 of 131
3. I
NTRODUCTION
3.1 Overview
FT-10 FILL filling controller is used for processing various type filling applications. It has 4 standard filling
modes for open container filling and above level bung hole filling and 2 modes for packing machines. The
controller has 4 opto-isolated digital input and 5 relay contact outputs.
3.2 Key features
FT
-10
FIL
L
FT
-10
FIL
L
P
B
FT
-10
FIL
L
P
N
FT
-10
FIL
L
E
N
FT
-10
FIL
L
CO
FT
-10
FIL
L
EI
FT
-10
FIL
L
EC
FT
-10
FIL
L
C
C
FT
-10
FIL
L
P
L
1 000 to 999 999 display resolution
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
High internal resolution up to 16 000 000 counts
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Up to 1600 conversion per second
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Serial interface RS 232C
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Serial interface RS 485
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Modbus RTU
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Modbus TCP
-
-
-
Yes
-
-
-
-
Profibus DPV1 interface
-
Yes
-
-
-
-
-
-
Profinet interface
-
-
Yes
-
-
-
-
-
Ethernet interface
-
-
-
Yes
-
-
-
-
CANopen interface
-
-
-
-
Yes
-
-
-
Ethernet IP interface
-
-
-
-
-
Yes
-
-
EtherCAT interface
-
-
-
-
-
-
Yes
-
CC-Link interface
-
-
-
-
-
-
-
Yes
Powerlink interface
Yes
Continuous data output
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Fast Continuous data output
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
BSI data interface
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
4 digital input and 5 relay contact output
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Error and at zero outputs (non-isolated)
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Programmable F key function ( total, t/h, Qtity or
last filling value )
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Auto-zero tracking
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Motion detection
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Zeroing and Taring by field bus command
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Adaptive digital filter for fast and stable reading
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Electronic calibration (eCal) without test weights
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Electronic calibration (eCal) over field bus
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Zero and Span calibrations over field bus
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Zero adjustment
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Span adjustment with test weights
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
Span adjustment for filled tanks
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
3 point calibration ( linearity correction )
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
8 load cells 350 Ω or 18 load cells 1100 Ω
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
12 to 28 VDC power supply range
Yes
Yes Yes Yes Yes Yes Yes Yes Yes