67
NO FLAVOR OR I
M
PROPER FLAVOR FL
OW
Corrective Action
Install a new
bag of syru
p
and prime the
syrup line
a
s
instructed.
Disassemble and clean
the Blending
Head
and orifice
s
as instructe
d
.
Plug the Keypad stereo
plug into the
Switch
jack until the
y
are fully e
ngaged.
Call for service or replace Spigot Switch.
Call for service or replace the switch
cable
(ELE 427) in the Keypad
.
Call for service.
Call for service or replace Spigot Switch.
Call for service or replace the switch
cable
(ELE 427) in the Keypad
.
Call for service or replace Spigot Switch.
Call for service or replace the switch
cable
(ELE 427) in the Keypad
.
Call for service or replace Spigot Switch.
Call for service or replace the switch
cable
(ELE 427) in the Keypad
.
Plug the Keypad stereo
plug into the
Switch
jack until the
y
are fully e
ngaged.
Refer to the TROUBLESHOOTING
GUIDE
“POWER UP PROBLEMS” to determine
probable ca
use and corr
ective a
c
tion
.
Probable Cause
The syrup b
ag is empty.
The orifices
of the Blending Head are
clogged.
The Switch stereo plug
and Keypad jack
are unplugg
ed or not fully engaged.
The Spigot Switch is fa
ulty.
The Keypad switch cable is fault
y
.
If an integrat
ed switch is
used, the switch
lever is no
t
activatin
g
th
e switch.
The Spigot Switch is fa
ulty and remains in
closed (active) position.
The Keypad switch cable is fault
y
.
The Spigot Switch may be faulty an
d
remains in closed (active) position.
The Keypad switch cable is fault
y
.
The Spigot Switch is fa
ulty.
The Keypad switch cable is fault
y
.
The Switch stereo plug
and Keypad jack
are unplugg
ed or not fully engaged.
There is no
power going to the Unit
and
Keypad.
Problem
There is no f
lavoring in
the product a
s
it is
drawn.
There is no f
lavoring in
the product,
and the
light on the
Keypad that
indicate
s th
e
selected f
lavor remains on after the p
roduct
is drawn.
The pump and Blending
Assembly st
art
immediately after the fla
v
or select
io
n key is
pressed.
The pump and Blending
Assembly continue
to operate a
fter the draw valve is clo
s
ed.
The syrup p
u
mp and the Blending
Assembly do not operat
e when the draw
valve is ope
ned.
The pump and the Blending Assembly do
not operate
when the draw valve is
opened,
and no LED’s light up on
the Keypad
.
Summary of Contents for FB 80Sa-08