48
4. Slide the coupler casing over the connection
and screw each coupler nut into each end of
the casing. Tighten the coupler nuts to
secure the connection. (See Figure 118.)
Figure 118
Installing & Filling the Sanitizer Tank
The Sanitizer Tank system provides approved
sanitizer solution to specific areas of the Flavor
Burst
®
system such as the Blending Head and
Syrup Lines during certain functions. In order
to utilize these clean-in-place functions, keep
an adequate supply of approved sanitizer
solution in the Sanitizer Tank at all times.
The Sanitizer Tank should be checked on a
daily basis, but only needs to be refilled if the
supply is low.
1. Prepare approximately 2 ½ gallons (9.5
Liters) of approved sanitizer solution
according to manufacturer’s instructions.
2. Insert one end of the sanitizer tube into the
fitting located at the lower back of the
cabinet. (See Figure 119.)
Figure 119
3. Insert the other end of the sanitizer tube into
the fitting on the Sanitizer Tank. (See
Figure 120.)
Figure 120
4. Remove the hand pump from the Sanitizer
Tank and fill the Tank with approved
sanitizer solution. (See Figure 121.)
Figure 121
NOTE:
USE THE REMAINING SANITIZER
SOLUTION FOR MANUAL SANITIZING IN
THE CLEAN-IN-PLACE PROCEDURE, DAILY
OPENING PROCEDURES, OR DAILY
CLOSING PROCEDURES.
5. Reinstall the hand pump and tighten
sufficiently. Using the handle, pump air into
the Sanitizer Tank to prime the pump
(approximately 10 strokes.) (See
Figure 122.)
Figure 122
NOTE:
NO PRESSURE IS NEEDED IN THE
TANK DURING NORMAL OPERATIONS.