38
2. Remove the worn o-ring from the Blending
Head. A small tool may be needed to
remove the o-ring in the syrup line opening.
(See Figure 82.)
Figure 82
3. Place the replacement o-ring in approved
sanitizer solution and soak for at least 1
minute. (See Figure 83.)
Figure 83
4. Place the 9-Tube Assembly in a container to
catch the sanitizer solution during the flush
function. (See Figure 84.)
Figure 84
5. Tilting the Blending Head downward, brush
and clean all exposed surfaces and
openings of the Blending Head with
detergent water, then rinse thoroughly. Use
a small brush to clean any syrup from the
syrup orifices. (See Figure 85.)
26064
Figure 85
NOTE:
DO NOT EXPOSE THE DRIVE
MOTOR TO MOISTURE.
6. Place only the Blending Head portion of the
Assembly in a container of detergent water.
Keep the Drive Motor upright and just above
the water line. Press the WATER / SYRUP
FLUSH key to clean the blending auger
inside the Blending Head. (See Figure 86.)
WATER
LINE
DRIVE
MOTOR
Detergent
26063
Figure 86
NOTE:
O-RINGS MUST BE COMPLETELY
SEATED TO PREVENT LEAKAGE.