Chapter 1 Outline
PAGE 1-4
☆
Fastening Result Record
Fastening resultant data is saved in a nonvolatile controller memory (approx. 12,000 cycles of data).
100 sets of torque curve data is stored in volatile memory (RAM).
100 sets of Reject curve data is stored in nonvolatile memory.
The fastening resultant data and the Reject curve data are therefore preserved even if the power is
turned off. However, the normal torque curve data is lost when the power is turned off. The above
data can be read with the User Console software.
●Fastening Result Storage Feature List of HFC3000 System
Function Name
Automatic Save
*1
Stored Data
HFC3000
User Console
Fastening
Data
Curve Data
Fastening Data
Setting Tab
Preferences
Auto Upload
Stored Data
Storage Content
Stored Data
Curve Data
Stored Data
Abnormals
Storage Location
PC
Each controller
Storable Records
-
12000
results
500 results
Setting Item
Yes
No
J
U
D
G
M
E
N
T
ACCEPT
○
○
○
REJECT
○
○
○
ABNORMAL
○
○
○
○
BYPASS
○
○
○
STOP
○
○
○
RESET
STOP
○
○
○
START OFF
○
○
○
*1
:
’Automatic Save’ must be enabled during data collection in the Fastening Data screen of
the AFC3000 User Console
Function Name
Stored Curve Data
CF Card
*2
HFC3000
User Console
Stored Curve Data
-
Storage Content
Stored Curve
Data *3
Stored Reject
Curve Data
Stored
Data
Curve Data
Storage Location
Each controller
CF Card
Storable Records
100 results
-
-
Storage Format
Torque-Angle (540deg)
-
Torque-Angle (180deg)
J
U
D
G
M
E
N
T
ACCEPT
○
○
○
REJECT
○
○
○
○
ABNORMAL
○
○
○
○
BYPASS
○
○
○
STOP
○
○
○
○
RESET
STOP
○
○
○
START OFF
○
○
○
○
*2
:
CF CARD Option and CF CARD are required separately.
*3
:
The stored (curve data) will be cleared when the control power of the controller is turned OFF.
Summary of Contents for Handheld Nutrunner HFC3000
Page 2: ...www fec usa com Copyright 2017 FEC AUTOMATION SYSTEMS All Rights Reserved ...
Page 14: ...Notes ...
Page 15: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Page 21: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Page 28: ...Chapter 2 Specifications PAGE 2 8 Blank Page ...
Page 29: ...Chapter 3 Sysytem Description PAGE 3 1 Chapter 3 System Description 3 ...
Page 36: ...Chapter 3 System Description PAGE 3 8 Memo ...
Page 37: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation Wiring 4 ...
Page 67: ...Chapter 5 Power Up and Operational Tests PAGE 5 1 Chapter 5 Power Up and Operational Tests 5 ...
Page 71: ...Chapter 6 Fastening Operation PAGE 6 1 Chapter 6 Fastening Operation 6 ...
Page 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 ...
Page 169: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 ...
Page 181: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 1 Chapter 9 Fieldbus I O Interfaces 9 ...
Page 229: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 49 Blank Page ...
Page 230: ......
Page 231: ......