Chapter 7 Troubleshooting
PAGE 7-9
Servo Amplifier Reply Errors [A.05 - *]
•
Code A05-01 - SERVO AMPLIFIER REPLY ERROR / NO REPLY FROM RESOLVER
The controller is attempting to turn the motor but is not receiving any signals back from the resolver to
indicate that the tool is actually turning or the speed reference on the amplifier is not responding.
CAUSE:
1. The tool cable is damaged or not connected.
2. When the resolver, motor or the controller malfunctions.
3. If there is excessive binding in the fastener, transmission or the spindle assembly keeping the
motor from turning.
4. System Parameter #523 (Fastening Current Limit) is not set to the correct value or set to 0% (may
be set too low).
5. Torque Transducer damage/error will not allow motor to start/turn.
RECOVERY:
1. Verify that the tool cable is securely connected at both ends and free from cuts, abrasive wear or
kinks
2. Connect a known good spare tool cable to the existing tool.
3. Exchange tool and/or controller with known working units. Reinitialize the system after exchanges.
4. Verify that System Parameter #523 [Fastening Current Limit] is set to the correct default value. (A
lower value than the default value will limit the current output of the controller to the value
programmed)
5. Inspect and correct any binding in the spindle assembly, transmission or fasteners.
Summary of Contents for Handheld Nutrunner HFC3000
Page 2: ...www fec usa com Copyright 2017 FEC AUTOMATION SYSTEMS All Rights Reserved ...
Page 14: ...Notes ...
Page 15: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Page 21: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Page 28: ...Chapter 2 Specifications PAGE 2 8 Blank Page ...
Page 29: ...Chapter 3 Sysytem Description PAGE 3 1 Chapter 3 System Description 3 ...
Page 36: ...Chapter 3 System Description PAGE 3 8 Memo ...
Page 37: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation Wiring 4 ...
Page 67: ...Chapter 5 Power Up and Operational Tests PAGE 5 1 Chapter 5 Power Up and Operational Tests 5 ...
Page 71: ...Chapter 6 Fastening Operation PAGE 6 1 Chapter 6 Fastening Operation 6 ...
Page 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 ...
Page 169: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 ...
Page 181: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 1 Chapter 9 Fieldbus I O Interfaces 9 ...
Page 229: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 49 Blank Page ...
Page 230: ......
Page 231: ......