Chapter 6 Fastening Operation
PAGE 6-21
6-4 Parameter Copy / Erasing the Fastening Result History / Formatting of the CF Card
NOTE: Copying parameters is performed easier using the HFC3000 Software
– this is provided in the
case software is not available
When multiple parameter sets need to be changed, one parameter can be copied to another parameter
while in the parameter edit mode.
Use the following procedure to copy parameters;
1. Operate the arrow pushbuttons to display
“Copy,” with “SYS” indicated in the PAR No. display and
“022” indicated in the D-No. display.
2. Press and hold the PROG button of the Controller
until the “022” blinks. Then press the [SET]
pushbutton and the COPY source/destination parameter numbers will appear in the upper
display.
3. Select the copy source parameter No. in the first 2 digits of the upper stage of the display (DATA).
4. Select the copy destination parameter No. in the last 2 digits of the upper stage of the display
(DATA).
5. Press the [SET] pushbutton, press the [
▲
] or [
▼
] pushbuttons to change the indication from
“Copy NO” to “Copy YES” within 2 seconds, and then press the [SET] pushbutton again within 2
seconds.
6.
Copying one parameter to another parameter is complete.
7. Press and hold the PROG button of the Controller until the "022" stops blink.
●
Batch Copying
Ex.
:
Copy parameter 1 to parameter 2
~
32
1. Operate the arrow pushbuttons
to make “Copy,” with “SYS” indicated in the PAR No. display and
“022” indicated in the D-No. display.
2. Press and hold the PROG button of the Controller
until the “022” blinks. Then press the [SET]
pushbutton and the COPY source/destination parameter numbers will appear in the upper
display.
3. Select the copy source parameter No. in the first 2 digits of the upper area of the display (DATA).
4. Select
“99” in the last 2 digits of the upper area of the display (DATA) and then press the [SET]
pushbutton.
5. Press the [
▲
] or [
▼
] pushbuttons to change
the indication from “Copy NO” to “Copy YES” within 2
seconds, and then press the [SET] pushbutton within 2 seconds.
6. Parameter 1 will be copied to parameter 2
~
32.
7. Press and hold the PROG button of the Controller until the "022" stops blinking.
Copy a parameter
to a parameter
Canceled if operation is not performed within 2 seconds.
Canceled if operation is not performed within 2 seconds.
Parameter
Batch Copy
[SET]
[▲] or [▼]
Copy Source Copy Destination
[SET]
[SET]
[▲] or [▼]
Copy Source
“99”
[SET]
Summary of Contents for Handheld Nutrunner HFC3000
Page 2: ...www fec usa com Copyright 2017 FEC AUTOMATION SYSTEMS All Rights Reserved ...
Page 14: ...Notes ...
Page 15: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Page 21: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Page 28: ...Chapter 2 Specifications PAGE 2 8 Blank Page ...
Page 29: ...Chapter 3 Sysytem Description PAGE 3 1 Chapter 3 System Description 3 ...
Page 36: ...Chapter 3 System Description PAGE 3 8 Memo ...
Page 37: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation Wiring 4 ...
Page 67: ...Chapter 5 Power Up and Operational Tests PAGE 5 1 Chapter 5 Power Up and Operational Tests 5 ...
Page 71: ...Chapter 6 Fastening Operation PAGE 6 1 Chapter 6 Fastening Operation 6 ...
Page 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 ...
Page 169: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 ...
Page 181: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 1 Chapter 9 Fieldbus I O Interfaces 9 ...
Page 229: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 49 Blank Page ...
Page 230: ......