Chapter 9 Fieldbus I/O Interfaces
PAGE 9-6
9-1-2 Fieldbus Message Output Format (HFC Tool
→
PLC Data Register)
ASCII Code :182 bytes fixed
(
Note: CCLINK is limited to 144byte transfer. If using CCLINK, the use of the ‘BANK: ON’ has been provided to
split the data block so all data may still be communicated. See format below)
Data Format in BANK : OFF
COUNT No. :
Incremented by (+1) each fastening
ACCEPT COUNT:
Counted number of ACCEPT fastening judgments
(JDG: Judgment, OCR: Occurrence)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
18
19 20 21 22
Date (Year: Lower 2 digits)
TIME
COUNT No.
ACCEPT
COUNT
31H 32H 2FH 30H 34H 2FH 31H 38H 31H 32H 3AH 33H 34H 3AH 35H 36H 30H 30H 30H 31H 30H 31H
1
2
/
0
4
/
1
8
1
2
:
3
4
:
5
6
0
0
0
1
0
1
23 24 25 26 27 28 29 30 31 32
33 34
35 36 37
38
39 40
41
42
Axis No.
Parametr No.
PEAK TORQUE
JDG
OCR
FINAL TORQUE
JDG
OCR
30H 31H 30H 31H 31H 32H 2EH 33H 34H 20H
20H
20H 31H 32H 2EH 33H 34H 20H
20H
20H
0
1
0
1
1
2
.
3
4
1
2
.
3
4
43 44 45 46 47
48
49
50
51
52 53 54
55 56 57
58
59
60
61
62
1ST PEAK TORQUE
2ND PEAK TORQUE
FINAL ANGLE
JDG
OCR
31H 32H 2EH 33H 34H 20H 31H 32H 2EH 33H 34H 20H 20H 20H 31H 32H 33H 20H 20H
20H
1
2
.
3
4
1
2
.
3
4
1
2
3
63 64 65 66 67
68
69
70
71
72 73 74
75 76 77
78
SIGN
DIFFERENTIAL ANGLE
JDG
OCR
SIGN
RATE 1
JDG
OCR
2DH 20H 20H
31H 33H 20H 20H 20H 20H 30H 2EH 31H 32H 33H 20H 20H
-
1
0
0
.
1
2
3
79 80 81 82 83
84
85
86
87
88 89 90
91 92 93
94
SIGN
RATE 2
JDG
OCR
SIGN
RATE 3
JDG
OCR
20H 30H 2EH
31H 32H 33H 20H 20H 20H 30H 2EH 31H 32H 33H 20H 20H
0
.
1
2
3
0
.
1
2
3
BANK[ON] START
95 96 97 98 99
100
101
102 103 104 105 106 107
108
109
110
1ST TIME
JDG
OCR
2ND TIME
JDG
OCR
20H 31H 30H 2EH 30H 20H 20H 20H 20H 20H 32H 2EH 30H 20H 20H 20H
1
0
.
0
2
.
0
111
112
113
114
115
116
117 118
119
120
121
122
123
124
125 126 127 128 129 130 131 132
CYCLE TIME
PEAK TORQUE CURRNT
PEAK TORQUE ANGLE
1ST RATE INC TOEQUE
20H 20H 33H 2EH
31H 20H 31H 37H 2EH 31H
20H 20H 20H 32H 30H 20H 20H 20H 31H 2EH 32H 20H
3
.
1
1
7
.
1
2
0
1
.
2
133
134
135
136
137
138
139 140
141
142
143
144
145
146
147
148 149 150
RATE1 INC ANGLE
RATE2 INC TOEQUE
RATE2 INC ANGLE
20H 20H 20H 20H
33H 20H 20H 20H 38H 2EH 39H 20H 20H
20H 20H 31H 37H 20H
3
8
.
9
1
7
151
152
153
154
155
156
157 158
159
160
161
162
163
164
165 166
RATE3 INC TOEQUE
RATE3 INC ANGLE
RUNDOWN REVO.
20H 20H 30H 2EH
30H 20H 20H 20H 20H
20H 30H 20H 20H
33H
2EH 35H
0
.
0
0
3
.
5
167
168
169
170
171
172
173 174
175
176
177
178
179
180
181 182
CALIBRATION VOLT
SIGN
ZERO VOLT
SNUG DETECTION TORQUE
JDG
32H 20H 31H 31H
20H 32H 36H 31H 20H
32H 2EH 33H 34H 20H 4FH 20H
2
5
1
1
2
6
1
2
.
3
4
O
SIGN
"
"(20H)
:+
data
"
-
"(2DH)
:-
data
JDG
"
O
"(4FH): ACCEPT
Summary of Contents for Handheld Nutrunner HFC3000
Page 2: ...www fec usa com Copyright 2017 FEC AUTOMATION SYSTEMS All Rights Reserved ...
Page 14: ...Notes ...
Page 15: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Page 21: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Page 28: ...Chapter 2 Specifications PAGE 2 8 Blank Page ...
Page 29: ...Chapter 3 Sysytem Description PAGE 3 1 Chapter 3 System Description 3 ...
Page 36: ...Chapter 3 System Description PAGE 3 8 Memo ...
Page 37: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation Wiring 4 ...
Page 67: ...Chapter 5 Power Up and Operational Tests PAGE 5 1 Chapter 5 Power Up and Operational Tests 5 ...
Page 71: ...Chapter 6 Fastening Operation PAGE 6 1 Chapter 6 Fastening Operation 6 ...
Page 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 ...
Page 169: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 ...
Page 181: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 1 Chapter 9 Fieldbus I O Interfaces 9 ...
Page 229: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 49 Blank Page ...
Page 230: ......
Page 231: ......