Chapter 9 Fieldbus I/O Interfaces
PAGE 9-29
9-3-3 I/O Signal Specifications
I/O Input/Output
Message Input/Output
Controller to PLC
PLC to Controller
Controller to PLC
PLC to Controller
Maximum
Setting
110 bytes (880 points)
110 bytes (880 points)
88 words
87 words
Standard
Setting
78bytes (624 points)
78 bytes (624 points)
88 words
87words
<Area per Station
・
1 Time Setting>
* PLC CC-
Link V1.10 Master Station▼
Type
1 Station Occupied
2 Stations Occupied
3 Stations Occupied
4 Stations Occupied
Number of
Occupied
Points
Number of
Available
Points
Number of
Occupied
Points
Number of
Available
Points
Number of
Occupied
Points
Number of
Available
Points
Number of
Occupied
Points
Number of
Available
Points
RX
32 points
*1
16 points
64 points
*1
48 points
96 points
*1
80 points
128 points
*1
112 points
RY
16 points
48 points
80 points
112 points
RWw
4 words
8 words
12 words
16 words
RWr
*2
3 words
7 words
11 words
15 words
<Area per Station
・
2 Times Setting>
Type
1 Station Occupied
2 Stations Occupied
3 Stations Occupied
4 Stations Occupied
Number of
Occupied
Points
Number of
Available
Points
Number of
Occupied
Points
Number of
Available
Points
Number of
Occupied
Points
Number of
Available
Points
Number of
Occupied
Points
Number of
Available
Points
RX
32
points
*1
16 points
96 points
*1
80 points
160 points
*1
144 points
224 points
*1
208 points
RY
16 points
80 points
144 points
208 points
RWw
8 words
16 words
24 words
32 words
RWr
*2
7 words
15 words
23 words
31 words
<Area per Station
・
4 Times Setting>
Type
1 Station Occupied
2 Stations Occupied
3 Stations Occupied
4 Stations Occupied
Number of
Occupied
Points
Number of
Available
Points
Number of
Occupied
Points
Number of
Available
Points
Number of
Occupied
Points
Number of
Available
Points
Number of
Occupied
Points
Number of
Available
Points
RX
64 points
*1
48 points
192 points
*1
176 points
320 points
*1
304 points
448 points
*1
432 points
RY
48 points
176 points
304 points
432 points
RWw
16 words
32 words
48 words
64 words
RWr
*2
15 words
31 words
47 words
63 words
<Area per Station
・
8 Times Setting> * Standard Setting
▼
Type
1 Station Occupied
2 Stations Occupied
3 Stations Occupied
4 Stations Occupied
Number of
Occupied
Points
Number of
Available
Points
Number of
Occupied
Points
Number of
Available
Points
Number of
Occupied
Points
Number of
Available
Points
Number of
Occupied
Points
Number of
Available
Points
RX
128 points
*1
112 points
384 points
*1
368 points
640 points
*1
624 points
896 points
*1
880 points
RY
112 points
368 points
624 points
880 points
RWw
32 words
64 words
88 words
*3
72 words
*3
RWr
*2
31 words
63 words
87 words
*3
71 words
*3
*1: 16 of the occupied points are used by the system area and the number of available points is decreased
accordingly.
*2: With RWr, 1 word is used for the error code and the area thereof is therefore 1 word less than that of RWw.
*3: The message input/output setting is restricted to a maximum of 256 bytes that is the total of the remote
input/output (RX/RY) and the remote registers (RWw/RWr) (640 88 words, 896 72 words).
Summary of Contents for Handheld Nutrunner HFC3000
Page 2: ...www fec usa com Copyright 2017 FEC AUTOMATION SYSTEMS All Rights Reserved ...
Page 14: ...Notes ...
Page 15: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Page 21: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Page 28: ...Chapter 2 Specifications PAGE 2 8 Blank Page ...
Page 29: ...Chapter 3 Sysytem Description PAGE 3 1 Chapter 3 System Description 3 ...
Page 36: ...Chapter 3 System Description PAGE 3 8 Memo ...
Page 37: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation Wiring 4 ...
Page 67: ...Chapter 5 Power Up and Operational Tests PAGE 5 1 Chapter 5 Power Up and Operational Tests 5 ...
Page 71: ...Chapter 6 Fastening Operation PAGE 6 1 Chapter 6 Fastening Operation 6 ...
Page 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 ...
Page 169: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 ...
Page 181: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 1 Chapter 9 Fieldbus I O Interfaces 9 ...
Page 229: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 49 Blank Page ...
Page 230: ......
Page 231: ......