FIRST START-UP
CARD G / FIT
15
V 6.15 E / April 2010
9.
FIRST START-UP
Hint:
Following numbers refer to the operating principle in chapter 6 on page 9.
9.1
C
OMPRESSED
A
IR
A
ND
E
LECTRICAL
C
ONNECTIONS
T
he power supply 1N~230V/50Hz or 2~220V/60Hz to the CARD G FIT is
to establish with the power cable delivered with the unit. The tables in chapter 7 / page 11 are
helpful to size the external fuses for the main power supply.
ATTENTION!
A grounding wire (PE) is included in the power cable. A locally tested
grounding system is crucial for safe operation of the CARD G FIT.
Compressed air is to be supplied by the customer and delivered to the hose connector (1.1) on
the CARD G FIT through the included compressed air hose.
The compressed air must be dehumidified and filtered. It must not
exceed a maximum pressure dew point of 5°C [41°C] at 7bar [102PSI]
and a residual oil content of 3mg/m³ [3ppm] to ensure a safe operation
and proper drying results!
The inner diameter of all compressed air lines leading to the CARD G
FIT must not be smaller than the inner diameter of the delivered
compressed air hose.
At all times, the air pressure at the compressed air inlet on the
CARD G FIT must be within minimum 6bar [87psi] and maximum 10bar
[145PSI].
Malfunctions during operation of venturi type loaders may occur if upper points are ignored. For
safe operation, it is important to ensure sufficient compressed air supply with minimum 6bar
[87PSI] according to the values for the compressed air consumption in chapter 7 on page 11 at
any time.
An external dry contact may be connected to pin 2 and 3 at the 4-poles plug (3.2) on the plug
panel to lower the drying temperature (S
LEEP
-Mode). The voltage to the external contact is
supplied by the CARD G FIT (24V DC – see wiring diagram in the annex).
Summary of Contents for CARD G
Page 2: ......
Page 11: ...HOW IT WORKS CARD G FIT 9 V 6 15 E April 2010 6 HOW IT WORKS ...
Page 26: ...MENU STRUCTURE CARD G FIT 24 V 6 15 E April 2010 12 MENU STRUCTURE ...
Page 27: ...MENU STRUCTURE CARD G FIT 25 V 6 15 E April 2010 12 1 EASY MODE ...
Page 28: ...MENU STRUCTURE CARD G FIT 26 V 6 15 E April 2010 ...
Page 29: ...MENU STRUCTURE CARD G FIT 27 V 6 15 E April 2010 12 2 EXTENDED MODE ...
Page 30: ...MENU STRUCTURE CARD G FIT 28 V 6 15 E April 2010 ...
Page 31: ...MENU STRUCTURE CARD G FIT 29 V 6 15 E April 2010 ...
Page 32: ...MENU STRUCTURE CARD G FIT 30 V 6 15 E April 2010 12 3 SYSTEM PARAMETERS ...
Page 33: ...MENU STRUCTURE CARD G FIT 31 V 6 15 E April 2010 ...
Page 92: ......
Page 93: ...ANNEX ...
Page 94: ......
Page 95: ......
Page 96: ......
Page 97: ......
Page 98: ......
Page 99: ......
Page 100: ......
Page 101: ......