FAULTS AND REMEDY
CARD G / FIT
76
V 6.15 E / April 2010
The FIT-controller shut down the process heater preemptively to avoid excess temperature in the
heater.
Solenoid valve (1.2) [3Y14] does not open when
drying is activated and pressure switch (1.3)
[2S5] is defective.
24V DC must be measurable at both
terminals (to ground) of the switch when
compressed air is available. Replace the
switch if needed
Check voltage supply 24VDC to valve; if OK,
replace valve.
Compressed air is missing and pressure switch
(1.3) [2S5] is defective.
Restore compressed air supply and replace
pressure switch.
Solid state relay [1V7] is defective.
There must be 220V...230V AC between L-
and N-(L2)wire of the heater when the solid
state relay is powered (green LED is ON)
if
not, replace SSR.
Heater (1.7) [1E7] defective.
Check heater resistance (290Ohm); if
necessary, replace heater.
This fault cannot be eliminated before
is pressed to switch off the drying process.
The safety thermostat of the process air heater (1.9) [3S8] has tripped.
Solenoid valve (1.2) [3Y14] does not open when
drying is activated and pressure switch (1.3)
[2S5] is defective.
24V DC must be measurable at both
terminals of the switch when compressed air
is available. Replace the switch if needed
Check voltage supply 24VDC to valve; if OK,
replace valve.
Compressed air is missing and pressure switch
(1.3) [2S5] is defective.
Restore compressed air supply and replace
pressure switch.
Solid state relay [1V7] is shorted.
There must not be 220V...230V AC between L-
and N-(L2)wire of the heater when the solid
state relay is not powered (green LED is
dark)
replace SSR if necessary.
Heater (1.7) [1E7] defective.
Check heater resistance (290Ohm); if
necessary, replace heater.
This fault cannot be eliminated before
is pressed to switch off the drying process.
Summary of Contents for CARD G
Page 2: ......
Page 11: ...HOW IT WORKS CARD G FIT 9 V 6 15 E April 2010 6 HOW IT WORKS ...
Page 26: ...MENU STRUCTURE CARD G FIT 24 V 6 15 E April 2010 12 MENU STRUCTURE ...
Page 27: ...MENU STRUCTURE CARD G FIT 25 V 6 15 E April 2010 12 1 EASY MODE ...
Page 28: ...MENU STRUCTURE CARD G FIT 26 V 6 15 E April 2010 ...
Page 29: ...MENU STRUCTURE CARD G FIT 27 V 6 15 E April 2010 12 2 EXTENDED MODE ...
Page 30: ...MENU STRUCTURE CARD G FIT 28 V 6 15 E April 2010 ...
Page 31: ...MENU STRUCTURE CARD G FIT 29 V 6 15 E April 2010 ...
Page 32: ...MENU STRUCTURE CARD G FIT 30 V 6 15 E April 2010 12 3 SYSTEM PARAMETERS ...
Page 33: ...MENU STRUCTURE CARD G FIT 31 V 6 15 E April 2010 ...
Page 92: ......
Page 93: ...ANNEX ...
Page 94: ......
Page 95: ......
Page 96: ......
Page 97: ......
Page 98: ......
Page 99: ......
Page 100: ......
Page 101: ......