PARAMETERS, VARIABLES & COMMANDS. ID
S
Mnem. Name
Level IDSER Ac
Min.
Max.
Def.
Units
Pag.
BV14
NotProgrammableIOs
Fagor 32972 RO
0
65535
-
-
CP1
CurrentProportionalGain
Fagor 00106 RW 0
999
-
-
CP2
CurrentIntegralTime
Fagor 00107 RW 0
999
-
-
CP20
CurrentLimit
Basic
33075 RW 0.00
50.00
0.00
A
CP30
CurrentCommandFilter1Type
Fagor 33076 RW 0
1
0
-
CP31
CurrentCommandFilter1Frequency
Fagor 33080 RW 0
4000
0
Hz
CP32
CurrentCommandFilter1Damping
Fagor 33081 RW 0
1000
0
Hz
CV1
Current1Feedback
User
33077 RO
-50.00
50.00
-
A
CV2
Current2Feedback
User
33078 RO
-50.00
50.00
-
A
CV3
CurrentFeedback
User
33079 RO
-50.00
50.00
-
A
CV10
Current1Offset
Fagor 33073 RO
-2.000
2.000
-
A
CV11
Current2Offset
Fagor 33074 RO
-2.000
2.000
-
A
DC1
ResetClass1Diagnostics
User
00099 RW 0
15
0
-
DC2
ClearHistoricOfErrorsCommand
User
33170 RW 0
15
0
-
DV17
HistoricOfErrors
User
33178 RO
-
-
-
-
DV31
DriverStatusWord
Fagor 00135 RO
0
65535
-
-
DV32
MasterControlWord
Fagor 00134 RW 0
65535
0
-
GC1
BackupWorkingMemoryCommand
Basic
00264 RW 0
15
0
-
GC3
SincoderAutoTunningCommand
Fagor 33498 RW 0
15
0
-
GC10
LoadDefaultsCommand
Basic
00262 RW 0
15
0
-
GP3
StoppingTimeout
Basic
33470 RW 0
9999
500
ms
GP5
ParameterVersion
Basic
33472 RO
-
-
-
-
GP9
DriveOffDelayTime
Basic
00207 RW 0
9999
50
ms
GP15
AutomaticInitialization
Fagor 33493 RW 0
1
1
-
GP16
MonoPhaseSelector
Basic
33495 RW 0
1
0
-
GV2
ManufacturerVersion
Basic
00030 RO
-
-
-
-
GV5
CodeChecksum
Basic
33474 RO
-
-
-
-
GV7
Password
Basic
00267 RW 0
9999
0
-
GV9
DriveType
Basic
00140 RO
-
-
-
-
GV11
SoftReset
Basic
33476 RW 0
16
0
-
GV16
MotorTableVersion
Basic
33484 RO
-
-
-
-
GV75
ErrorList
Fagor 00375 RO
-
-
-
-
HV5
PLDVersion
Basic
33063 RO
-
-
-
-
IP6
DigitalInputPolarity
User
33678 RW 0
1
0
-
IV10
DigitalInputs
User
33675 RO
0
1
-
-
KP3
ExtBallastPower
User
33882 RW 200
2000
200
W
KP4
ExtBallastEnergyPulse
User
33884 RW 200
2000
200
J
KV6
MotorTemperature
Basic
00383 RO
0
200
-
° C
KV10
CoolingTemperature
User
33870 RO
0
200
-
° C
KV32
I2tDrive
User
33877 RO
0
100
-
%
KV36
I2tMotor
User
33879 RO
0
100
-
%
KV40
I2tCrowbar
User
33883 RO
0
100
-
%
KV41
BallastSelect
User
33885 RW 0
1
1
-
MP1
MotorType
Basic
00141 RW -
-
-
-
MP2
MotorTorqueConstant
Fagor 33968 RW 0.00
10.00
10.00
N·m/A
MP3
MotorContinuousStallCurrent
Fagor 00111
RW 0.00
50.00
10.00
A
MP24
MotorMomentumOfInertia
Fagor 33988 RW 0.1
1000.0
-
kg·cm²
NP1
LoadMomentumOfInertiaPercentage
User
34968 RW 0.00
1000.00
0.00
%
NP116 ResolutionOfFeedback1
Fagor 00116
RO
0
65535
-
pulses
NP121 InputRevolutions
Fagor 00121 RW 1
65535
1
rev
NP122 OutputRevolutions
Fagor 00122 RW 1
65535
1
rev
Summary of Contents for ACSD series
Page 1: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives ACSD series Ref 1609 Original instructions ...
Page 6: ...ACSD 6 80 Digital Brushless AC Servo Drive system Ref 1609 This page intentionally left blank ...
Page 78: ...ACSD 78 80 Digital Brushless AC Servo Drive system Ref 1609 User notes ...
Page 79: ...Digital Brushless AC Servo Drive system Ref 1609 ACSD 79 80 User notes ...